208
[5] Tension Operation
Image diagram
No.
Position
[mm]
Velocity
[mm/s]
Accele-
ration
[G]
Decele-
ration
[G]
Pressing
[%]
Thresh-
old
[%]
Positioning
width
[mm]
Zone+
[mm]
Zone-
[mm]
Acceleration/
Deceleration
mode
Incre-
mental
Gain
set
Stop
mode
0
1
100.00
250.00
0.20
0.20
0
0
0.10
0.00
0.00
0
0
0
0
2
80.00
250.00
0.20
0.20
50
0
–50.00
0.00
0.00
0
0
0
0
3
Control method
The method of controlling the tension operation is the same as that described in [4] Pressing
operation. The control method is explained below by using the sample position table shown
above.
1) Position No.2 indicates the settings of tension operation. The settings of “Position” and
“Positioning width” show the tension start position and the tension quantity, respectively.
Attach – (minus sign) to the tension quantity. Specify the upper limit of the torque required
for tension in percent (limited current value) in “Pressing”. The speed, acceleration, and
deceleration are the conditions of positioning to the coordinate value (80mm) set in
“Position”.
2) Position No.1 indicates the tension start preparation position. Specify a value larger than
the coordinate value at which the tension provided by position No.2 ends (80 – 50 =
30mm) in “Position”.
3) First define the positioning in position No.1. Next, the operation in position No.2 moves
the actuator to the position of 80mm at the setting speed and rating torque and change to
the tension operation. The actuator moves by 50mm in the negative direction in the
tension operation. The upper limit of the tensile force is the torque set in percent.
4) In the similar way as pressing, the positioning complete signal is output when the shaft is
stopped by tension (pressing complete). If the actuator cannot be stopped during
movement within the setting positioning width (miss-pressing), it moves by the setting
distance to stop but PEND is not turned ON.
CSTR
Tension Operation
CSTR
Approach operation
Tension Operation
CSTR: Start position
Tension start position
80mm
Tension end position
80 – 50 = 30mm
Position No.1
Position No.2
3.8 Control and functions of Input and output signals of Remote I/O Mode
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......