66
Operation
Mode
Contents
Overview
Positioner 5
Mode
This is the operation mode of
the position data of 16 points at
maximum set in the position
table.
It is a mode that enabled to
monitor the current position in
0.1mm unit by reducing the
volume and number of position
table from Positioner 2 Mode.
Communication with Fieldbus
Dedicated Cable
+24V
Target Position No.
Control Signal
PLC
Current Position
Completed Position No.
Status Signal
Electric Cylinder
Remote I/O
Mode
It is the operation mode to
control with ON/OFF of bits like
PIO (24V input and output).
Five types
(Note 1)
of control are
available.
Note : It is to be switched with
PIO patterns (driver
board parameters)
Communication with Fieldbus
+24V
Target Position No.
Control Signal
PLC
Completed Position No.
Status Signal
Dedicated Cable
Electric Cylinder
Note
1: Five types
of control (PIO Pattern)
[Refer to the 3.4.10 Control Signal for Remote I/O
Mode for details.]
PIO Pattern
Operation Mode
I/O Specification
0
Positioning mode
Position number specification 64 points
Zone signal output 1 point
Position zone signal output
(Note 2)
1 point
1
Teaching mode
Positioning points 64 points
Position zone signal output
(Note 2)
1 point
Jog operation is available
The current position can be written to a specified position.
2
256-point mode
Positioning points 256 points
Position zone signal output
(Note 2)
1 point
4
Solenoid valve
mode 1
Positioning points 7 points
Zone signal output
1 point
(Note 1)
Position zone signal output
(Note 2)
1 point
Operation command available only with position number
indication
5
Solenoid valve
mode 2
Positioning points 3 points
Zone signal output
1 point
(Note 1)
Position zone signal output
(Note 2)
1 point
The actuator is operated by specifying forward, backward and
intermediate position commands.
Complete signal is able to output a signal equivalent to the
limit switch
Note
2: The position zone signal is able to switch to the zone signal in the setting of Parameter
No. 149.
3.1 Basic Operation
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......