360
3) Dummy plug
Connect a dummy plug to the teaching pendant connecting connector.
Make sure to connect a dummy plug if the AUTO mode is specified.
Without the connection, it will be the emergency stop condition.
Model : DP-4S
DP-4S
Plug
:
HDR-E26MSG1
10.2 When Connecting Power Supply with + Grounding
When using with + grounding, there is a risk of short-circuit of 24V DC power supply if
connected to the PC. This is because many PCs have the communication ground (GND) and
the frame ground (FG) connected inside and short-circuit occurs through the frame ground.
Also, if controllers with different 24V DC power supplies are connected with serial
communication, the communication line may become the route of controller power supply in
some cases depending on the timing to turn on the power, resulting in the malfunction of the
communication line.
Troubleshooting is summarized separately in [ME0271 Caution for + Grounding 24V Power
Controller]. Please refer to it.
Chapter 10
Appendix
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......