139
Set the parameter No.25 of MCON
Solenoid valve mode 1
Solenoid valve mode 2
4
5
Category
Port
No.
Symbol
Signal Name
Symbol
Signal Name
0
ST0
Start position 0
ST0
Start position 0
1
ST1
Start position 1
ST1
(JOG+)
Start position 1
2
ST2
Start position 2
ST2
(No
function)
Start position 2
3
ST3
Start position 3
–
4
ST4
Start position 4
–
5
ST5
Start position 5
–
6
ST6
Start position 6
–
7
–
–
8
–
Unavailable
–
Unavailable
9
BKRL
Brake release
BKRL
Brake release
10
–
Unavailable
–
Unavailable
11
HOME
Home return
–
12
*STP
Pause
–
13
–
Unavailable
–
Unavailable
14
RES
Reset
RES
Reset
PLC output
→
MCON input
15
SON
Servo ON command
SON
Servo ON Command
0
PE0
Position 0 complete
LS0
Retrieval to the Edge
Commands 0
1
PE1
Position 1 complete
LS1
(TRQS)
Retrieval to the Edge
Commands 1
2
PE2
Position 2 complete
LS2
(No
function)
Retrieval to the Edge
Commands 2
3
PE3
Position 3 complete
–
4
PE4
Position 4 complete
–
5
PE5
Position 5 complete
–
6
PE6
Position 6 complete
–
Unavailable
7
ZONE1
Zone 1
ZONE1
Zone 1
8
(Note 1)
PZONE/
ZONE2
Position zone/
Zone 2
PZONE/
ZONE2
Position zone/
Zone 2
9
–
Unavailable
–
Unavailable
10
HEND
Home return completion
HEND
Home return completion
11
PEND
Positioning completion signal
–
Unavailable
12
SV
Operation preparation end
SV
Operation preparation end
13
*EMGS
Emergency stop
*EMGS
Emergency stop
14
*ALM
Alarm
*ALM
Alarm
MCON output
→
PLC input
15
LOAD/TR
QS
*ALML
Torque check
(Note 2)
/
Light malfunction output
*ALML
Light malfunction output
Note 1 It is available to change in Parameter No. 149 Zone Output Switchover.
Note 2 It is available to change in Parameter No. 156 Torque Inspection / Light Malfunction Output Select for the pulse
motor driver.
It is the light malfunction output for the servo motor driver / brushless DC motor driver.
(Note) Brackets in the symbol names shown above are the functions before home-return operation.
(Note) “*” in codes above shows the signal of the active low. ( A signal of active low is a signal that the input signal is
processed when it is turned OFF, output signal is ordinarily on while the power is ON, and turns OFF when the
signal is output. )
3.4 Fieldbus
Type
Address Map
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......