296
[17] PIO jog velocity (Parameter No.26)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
26 PIO Jog Velocity
JOGV
mm/s
[deg/s]
1 to 250 (250 or less
of actuator
maximum speed)
In accordance
with actuator
The setting of JOG operation velocity when the set in the JOG velocity / inching distance
switchover signal JVEL is set to OFF.
Set an appropriate value in Parameter No.26 in accordance with the purpose of use.
[18] Movement command type (Parameter No.27)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
27 Movement Command Type
MCT
-
0 : Level
1 : Edge
0
Set the input methods for the start signal (ST0 to ST6, or ST0 to ST2 if PIO Pattern = 5) when
PIO Pattern 4 = Solenoid Valve Mode 1 (7-point type) and PIO Pattern 5 = Solenoid Valve
Mode 2 (3-point type).
Set Value Input Method
Description
0
Level
The actuator starts moving when the input signal turns ON.
When the signal turns OFF during movement, the actuator will
decelerate to a stop and complete its operation.
1
Edge
The actuator starts moving when the rising edge of the input signal
is detected. The actuator will not stop when the signal turns OFF
during the movement, until the target position is reached.
[Level System]
[Edge System]
Move command input (ST0 to ST6)
Movement complete (PE0 to PE6)
Actuator movement
Target Position
Stop
Move command input (ST0 to ST6)
Movement complete (PE0 to PE6)
Actuator movement
Target Position
Chapter 8 Parameter
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......