58
2) CC-Link Type
WT (DB)
BL (DA)
Shield (SLD)
YW (DG)
Connector Name CC-Link Connector
Cable Side
MSTB2.5/5-STF-5.08 AU
Enclosed in standard
package
Manufactured by
PHOENIX CONTACT
Controller Side
MSTB2.5/5-GF-5.08 AU
Pin No. Signal Name
(Color)
Description
Applicable cable
diameter
1
DA (BL)
Communication Line A
1
2
3
4
5
2
DB (WT)
Communication Line B
3
DG (YW)
Digital GND
4
SLD
Connect the shield of the
shielded cable (Connect the
FG of the 5 pins and
controller FG internally)
Front view of
connector on
controller side
5
FG
Frame Ground
(Connect the SLD of the 4
pins and controller FG
internally)
Dedicated cable for
CC-Link
(Note) Connect a terminal resistor between DA and DB if the unit comes to the
end of the network. [Refer to 2.2 [7] Wiring Layout for Fieldbus.]
Chapter 2 Wiring
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......