27
1.4 Specifications for each Fieldbus
1.4.1 Specifications of DeviceNet Interface
Item
Specification
DeviceNet2.0
Group 2 Dedicated Server
Communication Protocol
Network-Powered Insulation Node
Baud Rate
Automatically follows the master
Communication System
Master-Slave System (Polling)
Number of Occupied Channels
Refer to 3.4.1 PLC Address Construction by each Operation Mode
Number of Occupied Nodes
1 Node
Baud Rate
Max. Network
Length
Total Branch Line
Length
Max. Branch Line
Length
500kbps
100m
39m
250kbps
250m
78m
Communication Cable Length
(Note 1)
125kbps
500m
156m
6m
Communications Cable
Use the dedicated cable.
Connector
(Note 2)
MSTB2.5/5-GF-5.08 AU (Manufactured by PHOENIX CONTACT or equivalent)
Consumption Current of
Communication Power Supply
60mA
Communication Power Supply
24V DC (Supplied from DeviceNet)
Note 1 For T branch communication, refer to the Instruction Manuals for the master unit and programmable logic controller
(PLC) to be mounted.
Note 2 The cable-side connector is a standard accessory. [Refer to 1.1.1 Parts]
1.4.2 Specifications of CC-Link Interface
Item
Specification
Communication Protocol
CC-Link ver1.10 or ver2.00
Station Type
Remote Device Station (MAX. four stations occupied)
Baud Rate
10M/5M/2.5M/625k/156kbps
Communication System
Broadcast Polling System
Number of occupied stations
Refer to 3.4.1 PLC Address Construction by each Operation Mode
Baud Rate (bps)
10M
5M
2.5M
625k
156k
Communication Cable Length
(Note 1)
Total Cable Length (m)
100
160
400
900
1200
Communications Cable
Apply the dedicated cable
Connector
(Note 2)
MSTB2.5/5-GF-5.08 AU (Manufactured by PHOENIX CONTACT or equivalent)
Note 1 For T branch communication, refer to the Instruction Manuals for the master unit and PLC to be mounted.
Note 2 The cable-side connector is a standard accessory. [Refer to 1.1.1 Parts]
Chapter 1 Specifications Check
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......