321
[74] Selecting Automatic Current Reduction Feature (Parameter No.182)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
182 Auto Current Adj. Select
ACDS
-
0: Disabled
1: Enabled
0
It is a feature to make a stop by having the current flow considering the external force influence
when performing the complete stop in positioning.
It will be able to save the power consumption when the transported load is small.
[Refer to 6.2 Selecting Automatic Current Reduction Feature]
For pulse motor type only
Chapter 8 Parameter