304
[33] PIO jog velocity 2 (Parameter No.47)
No.
Name
Symbol
Unit
Input Range
Default
factory setting
47 PIO Jog Velocity 2
IOV2
mm/s
(
deg/s
)
1 to 250 (250 or
less of actuator
maximum speed)
In accordance
with actuator
The setting of JOG operation velocity when the set in the JOG velocity / inching distance
switchover signal JVEL is set to ON.
Set the appropriate value considering how the system is to be used.
However, it will operate at the value in this parameter only when JVEL Signal is on and
Command Speed Setting = 0 at the same time in the direct indication mode.
(Operation will be made at the Command Speed setting value when JVEL Signal is on and
Command Speed Setting ≠ 0.)
[34] PIO inch distance, PIO inch distance 2 (Parameter No.48, No.49)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
48
PIO Inching Distance
IOID
mm
[deg/s]
0.01 to 1.00
1.00
49
PIO Inching Distance 2
IOD2
mm
[deg/s]
0.01 to 1.00
0.10
When the selected PIO pattern is “1” (teaching mode), this parameter defines the inching
distance to be applied when inching input commands are received from the PLC.
Parameter No.49 defines the inching distance when 1 is set in the JOG speed / inching
distance switchover signal JVEL for field network type.
The maximum allowable value is 1mm.
[35] Load output judgment time period (Parameter No.50)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
50 Load Output Judgment Ttime
Period
LDWT
msec
0 to 9999
255
This parameter defines the time taken to judging whether torque level status signal (TRQS) is
ON.
If the command torque exceeds the value set in “Threshold” of position data for the time set by
this parameter during pressing operation, torque level status signal (TRQS) is turned ON.
Refer to 3.8.2 [4] or 3.8.3 [3] Pressing Operation for the details of the pressing operation.
[36] Torque inspected range (Parameter No.51)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
51 Torque Inspected Range
TRQZ
-
0 : Enabled
1 : Disabled
0
The load output (LOAD) turns ON when it exceeds the current [%] set as the position table
threshold in the range (check range) set with Zone +/Zone – in the position table during the
pressing operation.
For pulse motor type only
For pulse motor type only
Chapter 8 Parameter
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......