177
(16) Push-motion specification (PUSH) PLC Output Signal
Operation
Mode
Positioner 1
Simple Direct
Direct numeric
specification
Positioner 2
Positioner 3
Positioner 5
{
:
Equipped
×
:
Not equipped
×
×
{
×
×
×
When the movement command signal is output after this signal is turned ON, the pressing
operation is performed.
When this signal is set to “OFF”, the normal positioning operation is performed.
The same pressing type as CON related models such as PCON Controller or the same
pressing type as SEP related models such as PSEP can be selected for the pressing type in
Parameter No.181. Refer to 8.2 [73] for how to make selection.
[Pressing Operation CON Method]
After reaching the target position
(Note 1)
from the current position, the actuator moves with
the pressing speed for the distance set as the pressing band width.
The positioning complete signal (PEND) turns ON if the work piece hits and pressing is
judged as completed while in the pressing operation.
Note 1 In Direct Indication Mode, it is the value input in the target position register.
Speed
Movement distance
Target position
Pressing width (Max. pressing level)
Position where the actuator is pushed against
the work and the pressing completion is judged
so the positioning completion signal is turned “ON”
↓
[Pressing Operation SEP Method]
The pressing operation is performed with the start position set at the point in front of the
target position
(Note 1)
for the width of the positioning width (for Direct Indication Mode).
The positioning complete signal (PEND) turns ON if the work piece hits and pressing is
judged as completed while in the pressing operation.
Note 1 In Direct Indication Mode, it is the value input in the target position register.
(Note) Pulling operation cannot be performed.
Current position
↓
Pressing
start position
Speed
Target position
Positioning width
Position where the actuator is pushed against
the work and the pressing completion is judged
so the positioning completion signal is turned “ON”
3.7 Control and Functions of Input and Output Signals of Modes Other than Remote I/O Mode
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......