29
1.4.6 Specifications of EtherCAT Interface
Item
Specification
Communication Protocol
IEC61158 type 12
Physical Layer
100Base-TX (IEEE802.3)
Baud Rate
Automatically follows the master
Communication Cable Length
Follows EtherCAT® specifications (Distance between each node: 100m max.)
Slave Type
I/O slave
Available Node Addresses for Setting 0 to 127 (17 to 80 : When connected to the master (CJ1W-NC*82) manufactured by
OMRON)
Communications Cable
(Note 1)
Category 5 or more
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 Connector × 2pcs (Input × 1, Output × 1)
Connect
Daisy chain only
Note 1 Prepare separately for the communication cable.
1.4.7 Specifications of PROFINET-IO Interface
Item
Specification
Communication Protocol
IEC61158 (IEEE802.3), IEC61784
Baud Rate
100Mbps
Communication Cable Length
Distance between each segment: 100m Max.
Number of Connection
Master Unit
Available Node Addresses for Setting 0.0.0.0 to 255.255.255.255
Communications Cable
(Note 1)
Category 5 or more
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 Connector × 1pc
GSDML File Version
Ver 2.3
Note 1 Prepare separately for the communication cable.
1.4.8 Specifications of CC-Link IE Field Interface
Item
Specification
Communication Protocol
Conforms to IEEE802.3ab (1000BASE-T)
Baud Rate
1Gbps
Communications system
Token passing
Communication Cable Length
Distance between each segment: 100m Max.
Max. number of connected units
254 (total of master and slave stations)
Max. networks
239
Communications Cable
(Note 1)
Category 5e or more
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 Connector × 2pcs
Cyclic communication
RX (slave to master) : 16384 bits
RY (master to slave) : 16384 bits
RWr (slave to master) : 8192 words
RWw (master to slave) : 8192 words
Note 1 Prepare separately for the communication cable.
Chapter 1 Specifications Check
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......