(8) Pause (STP) PLC Output Signal
Operation
Mode
Positioner 1
Simple Direct
Direct numeric
specification
Positioner 2
Positioner 3
Positioner 5
{
:
Equipped
×
:
Not equipped
{
{
{
{
{
{
When this signal is turned ON, the actuator movement is decelerated and stopped. When it
is turned OFF, the actuator movement is restarted.
The acceleration in the operation restart or the deceleration in stopping operation, is
expressed as the value for the acceleration/deceleration for the position No. set using the
specified position No. resister in the Position* Mode and Simplified Direct Value Mode, and
as the value set in the acceleration/deceleration register in the Derect indication mode.
(9) Zone 1 (ZONE1)
PLC Input Signal
Zone 2 (ZONE2)
PLC Input Signal
Position Zone (PZONE)
PLC Input Signal
Operation
Mode
Positioner 1
Simple Direct
Direct numeric
specification
Positioner 2
Positioner 3
Positioner 5
{
:
Equipped
×
:
Not equipped
{
{
U
(No PZONE)
{
U
(Only for
PZONE1)
U
(No PZONE)
This is a function enables to turn a signal on while the actuator is passing a certain position
(in the zone range) or during a stop, in which there are two types.
1) Zone signal (ZONE1, ZONE2)···· Turn the output on at a position set in the parameter.
2) Position zone signal (PZONE) ···· Turn the output on at a position set in the position
table.
The roles of a sensor, such as the judgment of complete position at pressing complete,
continuous operation range setting for the pitch feed or operation interlock of other devices
in the setting range, can be made available.
(1) Zone signal (ZONE1, ZONE2)
Set the zone range to the parameter.
1) ZONE1: Parameter No.1 (Zone boundary 1+), Parameter No.2 (Zone boundary 1-)
2) ZONE2: Parameter No.23 (Zone boundary 2+), Parameter No.24 (Zone boundary 2-)
The zone signal is kept effective also during the emergency stop unless the memory of the
origin is lost due to alarm.
Time
Velocity
Zone output signal
1)
2)
3)
4)
5)
1)
2)
3)
4) 5)
3.7 Control and Functions of Input and Output Signals of Modes Other than Remote I/O Mode
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......