82
14) Stop mode ················ Automatic servo OFF is enabled after a certain period from the
completion of positioning for power saving.
Time setting is to be conducted in Parameter No. 36 to 38
Automatic Servo-off Delay Time 1 to 3, and three types of time
are available to select.
Selection is available from 0 to 3 for the servo motor type and
brushless DC motor type.
Selection is available from 0 to 7 for the pulse motor type.
Setting
Operation after Positioning
Complete
Selectable Type
0
Keep the servo ON
All types
1
Automatic servo-off in a certain time
(Parameter No. 36 set values)
All types
2
Automatic servo-off in a certain time
(Parameter No. 37 set values)
All types
3
Automatic servo-off in a certain time
(Parameter No. 38 set values)
All types
4
Full servo control
Pulse motor type
5
Full-servo control for a certain time
(Parameter No. 36 set values) and
then automatically turning servo
OFF
Pulse motor type
6
Full-servo control for a certain time
(Parameter No. 37 set values) and
then automatically turning servo
OFF
Pulse motor type
7
Full-servo control for a certain time
(Parameter No. 38 set values) and
then automatically turning servo
OFF
Pulse motor type
Caution:
y
No retaining torque is provided in automatic servo OFF. Pay sufficient
attention to the setting because the actuator may be moved by external force
applied to it.
y
Do not use the automatic servo OFF if the next moving command is relative
distance specification (pitch feed). Failure to follow it may cause position shift
to occur.
y
Do not use the automatic servo OFF in pressing. If used, the pressing force is
lost.
y
Automatic Servo OFF would not function in the operation with teaching mode
of PC software.
3.3 Setting of Position Data
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......