5.1 Triggering Measurement Start and Stop
135
3
5
Chapter 5 S
p
ecif
ying Crite
ria
for M
easurement
s
Enable the trigger function (set to On), select recording start/stop timing, and set trigger criteria.
Make these settings on the
[Trig & Alm]
screen.
See:
"Key Setting Procedure" (p .130)
Selecting Triggering Criteria (Trigger Source)
If trigger settings have been made on the
[CH]
screen, skip steps 1 and
2. (The settings in steps 1 and 2 are interlinked with those on the
[CH]
screen.)
1
Select the
[CH]
or
[Trig&Alm]
Screen.
2
Enable triggering
[On]
.
3
Select measurement start/stop timing.
(Start and stop triggers can be set for each channel
independently.)
4
Select trigger combining logic.
Interval triggers are not included in the above trigger
criteria, and start trigger events will occur when crite-
ria set with an interval trigger are satisfied.
See:
"Applying Trigger at Fixed Time Interval (Interval
Trigger)" (p .138)
Setting options: (
: default setting)
Start
Start recording according to
Start Trigger criteria.
Stop
Stop recording according to
Stop Trigger criteria.
Start/Stop
Start and stop recording according to the
Start and Stop Trigger criteria, respectively.
Setting options: (
: default setting)
OR
Triggering occurs when any one of the speci-
fied trigger source criteria is met.
(includes external trigger signal)
AND
Triggering occurs only when all of the specified
trigger source criteria are met.
(includes external trigger signal)
3
4
See:
"Using External
Triggering" (p .136)
[AND]
One waveform has crossed
above 0 V as the other
crosses on the upslope
[OR]
Either waveform crosses 0 V
on the upslope
Trigger: Level
Level: 0 V
Slope:
Triggering Criteria
To apply a trigger when the upslope (
) of the waveform crosses zero volts:
Start Measurement
T
T T
When
[AND]
is selected
No triggering occurs initially if
trigger criteria are already met when
measurement starts.
Before triggering can occur, trigger
criteria must first become invalid once.
T
T
Start Measurement
Содержание LR8410-20
Страница 1: ......
Страница 2: ......
Страница 12: ...Contents x...
Страница 32: ...Operating Precautions 20...
Страница 78: ...2 7 Compensating for Input Circuit Offset Zero Adjustment 66...
Страница 122: ...3 10 Viewing and Editing with the All Channel Settings List 110...
Страница 138: ...4 3 Marking Waveforms and Searching Marks Search Function 126...
Страница 222: ...9 4 Synchronous Measurements with Multiple instruments 210...
Страница 316: ...13 3 Disposing of the instrument 304...
Страница 360: ...Index Index 4...
Страница 361: ......
Страница 362: ......
Страница 363: ......
Страница 364: ......