Appendix 2 Error Messages and Remedial Actions
A
5
Appendix
239
CSV auto save has been set.
Unable to set the specified record
interval.
Select non-CSV auto saving to measure with the
specified recording interval.
240
The schedule has not been set
properly.
Check the schedule settings.
244
Auto-save has been changed from
CSV to waveform.
The saving method was changed to Waveform (bi-
nary) because the selected recording interval is too
short for CSV saving. To enable CSV saving, select
a longer recording interval or reduce the number of
channels used.
See:
"Automatic Saving (Waveform Data and
Numerical Calculation Results)" (p .163)
2
301
No waveform data.
No waveform data is preset, so data saving and cal-
culations cannot be performed. Press
START
to
start acquiring measurement data.
302
Confirm the A-B cursor position.
The A/B cursor positions are invalid (out of wave-
form range). Check the cursor positions.
303
No numerical calculation data.
Execute numerical calculation (p. 183)
304
Invalid event mark.
Try moving to an event mark that is not in memory.
401
File processing error.
An unexpected fault occurred while processing a file
on the removal storage. Turn the instrument off and
back on.
402
Cannot load this file.
The format of the file is incompatible with the instru-
ment, or the file is corrupt.
Refer to "6.1 About Saving and Loading Data" (p.
159) for loadable file formats.
403
Insert a Media.
A SD memory card or USB flash drive is not present.
Insert storage media.
405
Not enough capacity.
The removal storage as insufficient space to save
the file. Delete files to increase free space, or re-
place the removal storage.
406
Process interrupted
(not enough battery capacity).
The software cannot be updated with a low battery.
Power the instrument with the AC adapter or an ex-
ternal power supply, or charge the battery adequate-
ly first.
407
Insert SD memory card or USB
memory.
A SD memory card or USB flash drive is not present.
Insert storage media.
408
Preparing to protect files.
Wait approximately 10 minutes for the instrument’s
built-in high-capacity capacitor to charge.
430
Unsaved data present.
The removal storage is not inserted, or does not
have enough free space.
Insert a removal storage and manually save needed
data.
431
Insert media to save waveform data.
Insert a removal storage.
432
Change media.
Removable storage cannot be accessed. Replace
the SD memory card or USB flash drive.
Message
Remedial Action
Содержание LR8410-20
Страница 1: ......
Страница 2: ......
Страница 12: ...Contents x...
Страница 32: ...Operating Precautions 20...
Страница 78: ...2 7 Compensating for Input Circuit Offset Zero Adjustment 66...
Страница 122: ...3 10 Viewing and Editing with the All Channel Settings List 110...
Страница 138: ...4 3 Marking Waveforms and Searching Marks Search Function 126...
Страница 222: ...9 4 Synchronous Measurements with Multiple instruments 210...
Страница 316: ...13 3 Disposing of the instrument 304...
Страница 360: ...Index Index 4...
Страница 361: ......
Страница 362: ......
Страница 363: ......
Страница 364: ......