Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version 9.0.2.0
Introduced on the S6000.
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.1
Introduced on the S4810.
Usage
Information
Splitting a 40G port into 4x10G port is supported on standalone and stacked units.
Split ports cannot be used as stack-link to stack an S4810 system.
The quad port must be in a default configuration before it can be split into 4x10G
ports. The 40G port is lost in the config when the port is split, so be sure that the
port is also removed from other L2/L3 feature configurations.
The system must be reloaded after issuing the CLI for the change to take effect.
This command cannot be used if LR4 optics are inserted on the 40G interface.
Example (stack
unit – Warning
message when
13 ports are
configured in
any port range)
Dell(conf)#stack-unit 0 po 48 po q
Maximum number of ports that can be made Quad mode in the
range <0-63> is configured. Ports 52,56,60, will be disabled
on reload.
Do you wish to continue? [confirm yes/no]:yes
Please save and reset unit 0 for the changes to take effect.
Dell(conf)#
switchport
Place an interface in Layer 2 mode.
S4810
Syntax
switchport [backup interface {gigabit
slot/port
| tengigabit
slot/port
| fortyGigE
slot/port
| port-channel
number
}]
To remove an interface from Layer 2 mode and place it in Layer 3 mode, enter the
no switchport
command. If a switchport backup interface is configured, first
remove the backup configuration. To remove a switchport backup interface, enter
the
no switchport backup interface {gigabit slot/port |
tengigabit slot/port | fortyGigE slot/port | port-channel
number}
command.
Interfaces
801
Содержание Networking S4810
Страница 1: ...Dell Command Line Reference Guide for the S4810 System 9 4 0 0 ...
Страница 42: ...42 ...
Страница 62: ...62 ...
Страница 89: ... 12946259 bytes successfully copied Dell reload File Management 89 ...
Страница 90: ...90 ...
Страница 164: ...164 ...
Страница 204: ...204 ...
Страница 348: ...348 ...
Страница 518: ...518 ...
Страница 613: ...action act UpdateCounter param0 1 0x01 param1 0 0x00 output truncated Debugging and Diagnostics 613 ...
Страница 614: ...614 ...
Страница 652: ...652 ...
Страница 674: ...Version 8 3 12 0 Introduced on the S4810 674 FCoE Transit ...
Страница 686: ...686 ...
Страница 828: ...828 ...
Страница 838: ...838 ...
Страница 950: ...IPv6 Service Class Field Queue ID 101XXXXX 5 100XXXXX 4 011XXXXX 3 010XXXXX 2 001XXXXX 1 000XXXXX 0 950 IPv6 Basics ...
Страница 1036: ...1036 ...
Страница 1142: ...1142 ...
Страница 1156: ...1156 ...
Страница 1270: ...1270 ...
Страница 1386: ...1386 ...
Страница 1446: ...1446 ...
Страница 1448: ...1448 ...
Страница 1539: ...Gi1 2 2 STP PVST Dell Related Commands show running config displays the current configuration Service Provider Bridging 1539 ...
Страница 1540: ...1540 ...
Страница 1552: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell 1552 sFlow ...
Страница 1604: ...1604 ...
Страница 1642: ...1642 ...
Страница 1666: ...1666 ...
Страница 1676: ...1676 ...
Страница 1689: ... uplink state group creates an uplink state group and enables the tracking of upstream links Uplink Failure Detection UFD 1689 ...
Страница 1690: ...1690 ...
Страница 1710: ...1710 ...