Powered High Speed 
Short Range Modem:
Rack Mount Card

SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007
http://www.patton.com

Part# 07M1018RC-C
Doc# 013012UC
Revised 2/4/97

C E R T I F I E D

An ISO-9001

Certified Company

Содержание 1018RC

Страница 1: ...Powered High Speed Short Range Modem Rack Mount Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1018RC C Doc 013012UC Revised 2 4 97 C E R T I F I E D An ISO...

Страница 2: ...erms by the user 1 1 RADIO AND TV INTERFERENCE The Model 1018RC generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s in...

Страница 3: ...oint operation V 54 loopback tests and V 52 compliant BER tests Six easy to read LED indicators Transformer isolation Silicon Avalanche Diode surge protection Switchable 120V or 240V power supply Moun...

Страница 4: ...Patton factory default settings are found on on pages 4 and 5 S1 1 DTE Control of LAL The setting for switch S1 7 determines whether the Local Analog Loopback test on the Model 1018RC can be activated...

Страница 5: ...mbers are shown on the following page 8 S2 1 V 54 Disable The setting for switch S2 1 determines whether the Model 1018RC s V 54 diagnostics are disabled or are in normal operating mode S2 1 Setting O...

Страница 6: ...2 SGND DB 25 pin 7 and FRGND Connected Position 2 3 SGND DB 25 pin 7 and FRGND Not Connected 10 Interface Combination Model Number DB 25 RJ 11 1000RCM12511 DB 25 RJ 45 1000RCM12545 RJ 11 RJ 45 1000RC...

Страница 7: ...e rear interface cards compatible with the Model 1018RC has one terminal interface port and one 4 wire twisted pair port These cards provide a female DB 25 for the terminal interface connection 12 4 0...

Страница 8: ...5 to connect the terminal interface to your computing hardware It is pinned according to the EIA 561 DCE interface standard For specific interface pin outs please refer to the diagram in Appendix D of...

Страница 9: ...rror LED will glow A successful 511 E test will confirm that the loop is in place and that the Model 1018RC s built in 511 generator and detector are working properly 16 5 0 OPERATION Once you have co...

Страница 10: ...oth Model 1018RCs were functioning properly this suggests a problem with the twisted pair communication line connecting the two modems A common problem is improper crossing of the pairs Also verify th...

Страница 11: ...Wide Blank Front Panel 0516RPB1 Single Width Blank Rear Panel 0516RPB4 4 Wide Blank Rear Panel 056S1 Set of 16 4 pan head screws washers 20 APPENDIX B PATTON MODEL 1018RC CABLE RECOMMENDATIONS The Pa...

Страница 12: ...products for your unique needs We would like to hear from you Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs today and in th...