If the BER test indicates 

no errors are present,  move the V.52

toggle switch to the right, thus activating the “511/E” test with
periodic errors.  If the test is working properly, the red “Error”
LED will glow.  A successful “511/E” test will confirm that the
loop is in place, and that the Model 1018RC’s built-in “511”
generator and detector are working properly.

5.

If the BER test indicates that errors 

are present, check to see

that the RS-232 cable connecting the DTE to the Model
1018RC is wired straight through, and is plugged in properly.
Also, ensure that the Model 1018RC is configured properly.
Then re-check your DTE equipment.  If you still have errors,
call Patton Technical Support at (301) 975-1007.

5.2.2  REMOTE DIGITAL LOOPBACK (RDL)

The Remote Digital Loopback (RDL) test checks the performance of

both the local and remote Model 1018RCs, 

and the communication link

between them.  Any characters sent to the remote 1018RC in this test
mode will be returned back to the originating device.  For example,
characters typed on the keyboard of the local terminal will appear on
the local terminal screen 

after having been passed to the remote Model

1018RC and looped back.  To perform an RDL test, follow these steps:

1.

Activate RDL.  This may be done in two ways:  First, by
moving the upper front panel toggle switch LEFT to “Remote”.
Second, by raising pin 21 on the RS-232 interface.

2.

Verify that the DTE equipment on the local end is operating
properly and can be used for a test.

3.  Locate the lower of the two toggle switches on the front panel

of the 1018RC and move it to the left.  This will activate the
V.52 BER test mode and inject a “511” test pattern into the
remote loop.  If any errors are present in the loop, the red
“Error” LED will blink sporadically.

4.

If the BER test indicates 

no errors are present,  move the

V.52 toggle switch to the right, thus activating the “511/E” test
with periodic errors.  If the test is working properly, the red
“Error” LED will glow.  A successful “511/E” test will confirm
that the loop is in place, and that the Model 1018RC’s built-in
“511” generator and detector are working properly.

16

5.0  OPERATION

Once you have configured each Model 1018RC and connected the

cables, you are ready to operate the units.  Section 5.0 describes the
power-up procedure and the built-in V.54 and V.52 test modes.

5.1  POWER-UP

There is no power switch on the Model 1018RC:  Power is

automatically applied to the Model 1018RC when its card-edge
connector makes contact with the chassis’ mid-plane socket, or when
the chassis’ power supply is turned on.  

Note: The Model 1018RC is a

“hot swappable” card—it will not be damaged by plugging it in or
removing it while the rack is powered up.

5.2  TEST MODES

The Model 1018RC offers two V.54 test modes and two V.52 test

modes to evaluate the condition of the modems and the communication
link.  Both sets of tests can be activated physically from the front panel.
The V.54 test can also be activated from the RS-232 interface.

5.2.1  LOCAL ANALOG LOOPBACK (LAL)

The Local Analog Loopback (LAL) test checks the operation of the

local Model 1018RC, and is 

performed separately on each unit. Any

data sent to the local Model 1018RC in this test mode will be echoed
(returned) back to the user device.  For example, characters typed on
the keyboard of a terminal will appear on the terminal screen.  To
perform a LAL test, follow these steps:

1.

Activate LAL.  This may be done in one of two ways:  First, by
moving the upper front panel toggle switch RIGHT to “Analog”.
Second, by raising pin 18 on the RS-232 interface (note: be
sure DIP switch SW1-6 is enabled).  Once LAL is activated,
the Model 1018RC transmit output is connected to its own
receiver.  The “Test” LED should be lit.

2.

Verify that the data terminal equipment is operating properly
and can be used for a test.  

3.

Locate the lower of the two toggle switches on the front panel
of the Model 1018RC and move it to the left.  This will activate
the V.52 BER test mode and inject a “511” test pattern into the
local loop.  If any errors are present in the loop, the red “Error”
LED will blink sporadically.

15

Содержание 1018RC

Страница 1: ...Powered High Speed Short Range Modem Rack Mount Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1018RC C Doc 013012UC Revised 2 4 97 C E R T I F I E D An ISO...

Страница 2: ...erms by the user 1 1 RADIO AND TV INTERFERENCE The Model 1018RC generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s in...

Страница 3: ...oint operation V 54 loopback tests and V 52 compliant BER tests Six easy to read LED indicators Transformer isolation Silicon Avalanche Diode surge protection Switchable 120V or 240V power supply Moun...

Страница 4: ...Patton factory default settings are found on on pages 4 and 5 S1 1 DTE Control of LAL The setting for switch S1 7 determines whether the Local Analog Loopback test on the Model 1018RC can be activated...

Страница 5: ...mbers are shown on the following page 8 S2 1 V 54 Disable The setting for switch S2 1 determines whether the Model 1018RC s V 54 diagnostics are disabled or are in normal operating mode S2 1 Setting O...

Страница 6: ...2 SGND DB 25 pin 7 and FRGND Connected Position 2 3 SGND DB 25 pin 7 and FRGND Not Connected 10 Interface Combination Model Number DB 25 RJ 11 1000RCM12511 DB 25 RJ 45 1000RCM12545 RJ 11 RJ 45 1000RC...

Страница 7: ...e rear interface cards compatible with the Model 1018RC has one terminal interface port and one 4 wire twisted pair port These cards provide a female DB 25 for the terminal interface connection 12 4 0...

Страница 8: ...5 to connect the terminal interface to your computing hardware It is pinned according to the EIA 561 DCE interface standard For specific interface pin outs please refer to the diagram in Appendix D of...

Страница 9: ...rror LED will glow A successful 511 E test will confirm that the loop is in place and that the Model 1018RC s built in 511 generator and detector are working properly 16 5 0 OPERATION Once you have co...

Страница 10: ...oth Model 1018RCs were functioning properly this suggests a problem with the twisted pair communication line connecting the two modems A common problem is improper crossing of the pairs Also verify th...

Страница 11: ...Wide Blank Front Panel 0516RPB1 Single Width Blank Rear Panel 0516RPB4 4 Wide Blank Rear Panel 056S1 Set of 16 4 pan head screws washers 20 APPENDIX B PATTON MODEL 1018RC CABLE RECOMMENDATIONS The Pa...

Страница 12: ...products for your unique needs We would like to hear from you Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs today and in th...

Отзывы: