Page 1: ...H3C S12500R 2L Ethernt Switch Router Installation Quick Start New H3C Technologies Co Ltd http www h3c com Document version 5PW102 20200722 ...

Page 2: ...respective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accurate but they are presented without warranty of any kind express or implied H3C shall not be liable for technical or editorial errors or omissions contained herein Environmental protection This produc...

Page 3: ... protective blank panel 3 3 Installing an interface module 3 3 Removing an interface module 3 4 Installing a filler panel in an empty interface module slot 3 5 Installing cable management brackets 3 5 Installing and removing fan trays 3 6 Installing fan trays 3 6 Removing a fan tray 3 7 Installing and removing power supplies 3 8 Installing a power supply 3 8 Removing a power supply 3 8 Connecting ...

Page 4: ... be used indoors To ensure correct operation of the device and to prolong its service lifetime the installation site must meet the load bearing temperature humidity cleanliness EMI grounding power supply ventilation and space requirements Reserve a minimum clearance of 1 2 m 3 94 ft between the device and walls or other devices For more information see H3C S12500R 2L Switch Router Installation Gui...

Page 5: ...1 2 Table 1 1 Installation tools Name Description ESD wrist strap Marker Phillips screwdriver ...

Page 6: ...rom the rack facing surface of the mounting brackets to the front ends of the cable management brackets 909 mm 35 79 in from the rack facing surface of the mounting brackets to the power supply handles at the chassis rear A minimum of 1 1 m 3 61 ft in depth recommended A minimum of 130 mm 5 12 in from the front rack post to the front door A minimum of 950 mm 37 40 in from the front rack post to th...

Page 7: ...he four square holes on the rack posts 3 As shown in Figure 2 2 mark the cage nut installation holes on each rack post for installing the slide rails Make sure the installation holes are at the same height on the four rack posts On each front rack post mark the lower three aligned square holes The top aligned square hole will be blocked by the mounting bracket On each rear rack post mark the four ...

Page 8: ...ttaching mounting brackets Before mounting the chassis in the rack install cage nuts on the front rack posts for attaching the mounting brackets by performing the following steps 1 As shown in Figure 2 3 determine the cage nut installation holes and then mark them on the front rack post 2 Install cage nuts in the marked square holes on the front rack posts If you have installed screws in the marke...

Page 9: ...e device in the rack 1 Face the rear of the chassis towards the front of the rack 2 Move the device by holding the chassis handles 3 Place the device on the slide rails from the front of the rack and slide the device along the guide rails until the mounting brackets on the device touch the front rack posts tightly as shown by callout 1 in Figure 2 4 4 Use the provided M6 screws provided with the d...

Page 10: ...vice 1 Unpack the grounding cable The grounding cable provided with the device is compliant with the NEBS standards The two hole grounding lug of the grounding cable is used for connecting the chassis The ring terminal of the grounding cable is used for connecting the grounding strip 2 Remove the two M6 grounding screws from the grounding holes at the rear of the chassis A grounding sign is provid...

Page 11: ...2 6 Figure 2 5 Connecting the grounding cable 1 Grounding sign 2 Use grounding screws to attach the two hole grounding lug to the grounding point 1 2 ...

Page 12: ...gure 1 1 for attaching an ESD wrist strap Installing and removing SEUs CAUTION If you are not to install an SEU in an SEU slot keep the filler panel in the slot When you install an SEU avoid damaging the connectors on the SEU You can install one SEU or two SEUs for redundancy on the device If you are to install one SEU install it in either of the SEU slots Installing an SEU 1 As shown by callout 1...

Page 13: ...Hold the ejector lever to pull the SEU part way out of the slot See callout 2 in Figure 3 2 3 Holding the SEU by the front panel with one hand and supporting the bottom with the other pull the SEU steadily out of the slot along the guide rails Keep the SEU parallel to the slot to avoid touching other components in the chassis 1 2 3 4 ...

Page 14: ...otective blank panel 1 Remove the screws that secure the protective blank panel to the device See callout 1 in Figure 3 3 2 As shown by callout 2 in Figure 3 3 remove the protective blank panel with both hands Keep the removed protective blank panel and screws secure for future use Figure 3 3 Removing the protective blank panel Installing an interface module The ejector levers of the interface mod...

Page 15: ...ers touch the slot edges tightly 5 As shown by callout 3 in Figure 3 4 continue to push the interface module by its middle part on the front panel until you cannot move it 6 As shown by callout 4 in Figure 3 4 push the ejector levers inward until they come in close contact with the panel 7 As shown by callout 5 in Figure 3 4 fasten the captive screws to secure the interface module to the chassis T...

Page 16: ...e module slot filler panel is provided with the device If you are not to install an interface module in an interface module slot install the filler panel in the slot To install a filler panel in an empty interface module slot 1 As shown by callout 1 in Figure 3 6 align the two captive screws on the filler panel with the installation holes on the slot 2 As shown by callout 2 in Figure 3 6 fasten th...

Page 17: ...the failed fan tray in position before the replacement To install a fan tray in slot FAN1 orient the fan tray so that the LED is on the left side of the front panel To install a fan tray in slot FAN2 orient the fan tray so that the LED is on the right side of the front panel To avoid damaging the fan tray use both hands when installing or removing a fan tray When you hot swap a fan tray only one f...

Page 18: ...rocedure removes the fan tray from the FAN1 slot 1 As shown by callout 1 in Figure 3 9 loosen the captive screws on the fan tray 2 Squeezing the captive screw at the air vents side with one hand and holding the fan tray handle pull the fan tray outward until it is disengaged from the chassis Remove the fan tray after the fan stops rotating Figure 3 9 Removing a fan tray 1 2 2 1 1 2 ...

Page 19: ... supply 1 Remove the filler panel from the target power supply slot As shown by callout 1 in Figure 3 10 put your forefinger into the hole of the filler panel and pull the filler panel out of the slot along the guide rails 2 As shown by callout 2 in Figure 3 10 holding the power supply handle with one hand and supporting the power supply bottom with the other slide the power supply along the guide...

Page 20: ...llout 2 in Figure 3 11 Figure 3 11 Removing a power supply Connecting the power cord CAUTION Power on the device after you have completed installation Prepare a separate circuit breaker for power input of each power cord Turn off the circuit breaker before you connect the power cord Connecting the AC power cord 1 Plug the AC power cord connector into the AC input receptacle of the power supply 2 U...

Page 21: ...er over the wiring terminals and use a Phillips screwdriver to remove the M5 screws The recommended torque is 20 kgf cm 1 96 Nm 2 Connect the wire marked with the negative polarity symbol to the negative terminal on the power supply Connect the wire marked with the positive polarity symbol to the positive terminal on the power supply 3 Fasten the M5 screws to secure the wires and then install the ...

Page 22: ... Optional Installing transceiver modules CAUTION To prevent particles from entering the ports install the dust plugs that come with the interface modules in the QSFP QSFP28 ports if you are not to install transceiver modules or cables in the ports ...

Page 23: ...ule up Holding the module gently push the module into the slot until it has firm contact with the slot as shown in Figure 3 14 For a module that uses a plastic pull latch skip this step If you cannot hold the module by its two sides because of high module density press the module on its head end to push it in Figure 3 14 Installing a QSFP QSFP28 module Connecting a QSFP QSFP28 cable CAUTION When y...

Page 24: ...ds take consideration of the layout of the equipment room including the locations of the power distribution cabinet AC power receptacles and lightning protection box Ensure safety when routing power cords The power supplies of the device are located on the far left and far right of the rear panel As a best practice route power cords for the left power supplies from left of the device and route pow...

Page 25: ... console cable 1 Plug the DB 9 female connector of the console cable to the serial port of the PC 2 Plug the RJ 45 connector of the console cable to the console port of the device Figure 5 1 Connecting a terminal to the console port Verification before login Before you log in to the device perform the following tasks Verify that the device has been correctly installed Verify that all modules have ...

Page 26: ...33MHz flash Size 7296MB CPLD 1 Version 0 0 CPLD 2 Version 0 0 CPLD 3 Version 0 0 PCB Version Ver A BootWare Validating Press Ctrl B to access EXTENDED BOOTWARE MENU Loading the main image files Loading file flash SYSTEM bin Done Loading file flash BOOT bin Done Image file flash BOOT bin is self decompressing Done System image is starting Line aux1 0 is available Press ENTER to get started Press En...