online stack-unit
Place a stack unit in the online state.
S4810
Syntax
online stack-unit
number
Parameters
number
Enter the stack-unit number. The S4810 range is from 0 to
11.
Defaults
none
Command
Modes
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version 9.0.2.0
Introduced on the S6000.
Version
8.3.19.0
Introduced on the S4810.
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 7.7.1.0
Introduced on the S-Series.
Usage
Information
You cannot enter this command on a Master or Standby unit.
The system reboots when the off-line diagnostics complete. This reboot is an
automatic process. A warning message appears when the
offline stack-unit
command is implemented.
Warning - Diagnostic execution will cause stack-unit to reboot
after completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
Related
Commands
show environment (S-Series)
— views the S-Series system component status (for
example, temperature, voltage).
598
Debugging and Diagnostics
Содержание Networking S4810
Страница 1: ...Dell Command Line Reference Guide for the S4810 System 9 4 0 0 ...
Страница 42: ...42 ...
Страница 62: ...62 ...
Страница 89: ... 12946259 bytes successfully copied Dell reload File Management 89 ...
Страница 90: ...90 ...
Страница 164: ...164 ...
Страница 204: ...204 ...
Страница 348: ...348 ...
Страница 518: ...518 ...
Страница 613: ...action act UpdateCounter param0 1 0x01 param1 0 0x00 output truncated Debugging and Diagnostics 613 ...
Страница 614: ...614 ...
Страница 652: ...652 ...
Страница 674: ...Version 8 3 12 0 Introduced on the S4810 674 FCoE Transit ...
Страница 686: ...686 ...
Страница 828: ...828 ...
Страница 838: ...838 ...
Страница 950: ...IPv6 Service Class Field Queue ID 101XXXXX 5 100XXXXX 4 011XXXXX 3 010XXXXX 2 001XXXXX 1 000XXXXX 0 950 IPv6 Basics ...
Страница 1036: ...1036 ...
Страница 1142: ...1142 ...
Страница 1156: ...1156 ...
Страница 1270: ...1270 ...
Страница 1386: ...1386 ...
Страница 1446: ...1446 ...
Страница 1448: ...1448 ...
Страница 1539: ...Gi1 2 2 STP PVST Dell Related Commands show running config displays the current configuration Service Provider Bridging 1539 ...
Страница 1540: ...1540 ...
Страница 1552: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell 1552 sFlow ...
Страница 1604: ...1604 ...
Страница 1642: ...1642 ...
Страница 1666: ...1666 ...
Страница 1676: ...1676 ...
Страница 1689: ... uplink state group creates an uplink state group and enables the tracking of upstream links Uplink Failure Detection UFD 1689 ...
Страница 1690: ...1690 ...
Страница 1710: ...1710 ...