Line
Description
Power Low
Warning threshold
Factory-defined setting. Value can differ between SFP and
SFP+.
Temperature
Current temperature of the SFPs. If this temperature crosses
Temp High alarm/warning thresholds, the temperature high
alarm/warning flag is set to true.
Voltage
Current voltage of the SFPs. If this voltage crosses voltage
high alarm/warning thresholds, the voltage high alarm/
warning flag is set to true.
Tx Bias Current
Present transmission (Tx) bias current of the SFP. If this
crosses bias high alarm/warning thresholds, the TX bias high
alarm/warning flag is set to true. If it falls below the low
alarm/warning thresholds, the TX bias low alarm/warning
flag is set to true.
Tx Power
Present Tx power of the SFP. If this crosses Tx power alarm/
warning thresholds, the Tx power high alarm/warning flag is
set to true. If it falls below the low alarm/warning
thresholds, the Tx power low alarm/ warning flag is set to
true.
Rx Power
Present receiving (Rx) power of the SFP. This value is either
average Rx power or OMA. This depends on the Rx Power
measurement type displayed above. If this crosses Rx power
alarm/warning thresholds, the Rx power high alarm/warning
flag is set to true. If it falls below the low alarm/warning
thresholds, the Rx power low alarm/warning flag is set to
true.
Data Ready state
Bar
This field indicates that the transceiver has achieved power
up and data is ready. This is set to true if data is ready to be
sent and set to false if data is being transmitted.
Rx LOS state
This is the digital state of the Rx_LOS output pin. This is set
to true if the operating status is down.
Tx Fault state
This is the digital state of the Tx Fault output pin.
Rate Select state
This is the digital state of the SFP rate_select input pin.
RS state
This is the reserved digital state of the pin AS(1) per
SFF-8079 and RS(1) per SFF-8431.
Tx Disable state
If the admin status of the port is down then this flag is set to
true.
Temperature High
Alarm Flag
This can be either true or false, depending on the Current
voltage value displayed above.
Voltage High
Alarm Flag
This can be either true or false, depending on the Current
Temperature value displayed above.
792
Interfaces
Содержание Networking S4810
Страница 1: ...Dell Command Line Reference Guide for the S4810 System 9 4 0 0 ...
Страница 42: ...42 ...
Страница 62: ...62 ...
Страница 89: ... 12946259 bytes successfully copied Dell reload File Management 89 ...
Страница 90: ...90 ...
Страница 164: ...164 ...
Страница 204: ...204 ...
Страница 348: ...348 ...
Страница 518: ...518 ...
Страница 613: ...action act UpdateCounter param0 1 0x01 param1 0 0x00 output truncated Debugging and Diagnostics 613 ...
Страница 614: ...614 ...
Страница 652: ...652 ...
Страница 674: ...Version 8 3 12 0 Introduced on the S4810 674 FCoE Transit ...
Страница 686: ...686 ...
Страница 828: ...828 ...
Страница 838: ...838 ...
Страница 950: ...IPv6 Service Class Field Queue ID 101XXXXX 5 100XXXXX 4 011XXXXX 3 010XXXXX 2 001XXXXX 1 000XXXXX 0 950 IPv6 Basics ...
Страница 1036: ...1036 ...
Страница 1142: ...1142 ...
Страница 1156: ...1156 ...
Страница 1270: ...1270 ...
Страница 1386: ...1386 ...
Страница 1446: ...1446 ...
Страница 1448: ...1448 ...
Страница 1539: ...Gi1 2 2 STP PVST Dell Related Commands show running config displays the current configuration Service Provider Bridging 1539 ...
Страница 1540: ...1540 ...
Страница 1552: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell 1552 sFlow ...
Страница 1604: ...1604 ...
Страница 1642: ...1642 ...
Страница 1666: ...1666 ...
Страница 1676: ...1676 ...
Страница 1689: ... uplink state group creates an uplink state group and enables the tracking of upstream links Uplink Failure Detection UFD 1689 ...
Страница 1690: ...1690 ...
Страница 1710: ...1710 ...