vrf
vrf-name
Enter the keyword
vrf
followed by the name of the VRF to
show information corresponding to the OSPF neighbors that
are tied to a specific VRF.
Command
Modes
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version 9.4.
(0.0)
Added support for VRF.
Version 9.0.2.0
Introduced on the S6000..
Version
8.3.19.0
Introduced on the S4820T.
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 7.8.1.0
Added support for Multi-Process OSPF.
Version 7.6.1.0
Introduced on the S-Series.
Version 7.5.1.0
Introduced on the C-Series.
pre-Version
6.1.1.1
Introduced on the E-Series.
Usage
Information
The following describes the
show ip ospf
process-id
neighbor
command
shown in the following example.
Item
Description
Neighbor ID
Displays the neighbor router ID.
Pri
Displays the priority assigned neighbor.
State
Displays the OSPF state of the neighbor.
Dead Time
Displays the expected time until FTOS declares the neighbor
dead.
Address
Displays the IP address of the neighbor.
Interface
Displays the interface type slot/port information.
Area
Displays the neighbor’s area (process ID).
Example
Dell#show ip ospf 34 neighbor
Neighbor ID Pri State Dead Time Address Interface Area
20.20.20.7 1 FULL/DR 00:00:32 182.10.10.3 Gi 0/0 0.0.0.2
192.10.10.2 1 FULL/DR 00:00:37 192.10.10.2 Gi 0/1 0.0.0.1
Open Shortest Path First (OSPFv2 and OSPFv3)
1225
Содержание Networking S4810
Страница 1: ...Dell Command Line Reference Guide for the S4810 System 9 4 0 0 ...
Страница 42: ...42 ...
Страница 62: ...62 ...
Страница 89: ... 12946259 bytes successfully copied Dell reload File Management 89 ...
Страница 90: ...90 ...
Страница 164: ...164 ...
Страница 204: ...204 ...
Страница 348: ...348 ...
Страница 518: ...518 ...
Страница 613: ...action act UpdateCounter param0 1 0x01 param1 0 0x00 output truncated Debugging and Diagnostics 613 ...
Страница 614: ...614 ...
Страница 652: ...652 ...
Страница 674: ...Version 8 3 12 0 Introduced on the S4810 674 FCoE Transit ...
Страница 686: ...686 ...
Страница 828: ...828 ...
Страница 838: ...838 ...
Страница 950: ...IPv6 Service Class Field Queue ID 101XXXXX 5 100XXXXX 4 011XXXXX 3 010XXXXX 2 001XXXXX 1 000XXXXX 0 950 IPv6 Basics ...
Страница 1036: ...1036 ...
Страница 1142: ...1142 ...
Страница 1156: ...1156 ...
Страница 1270: ...1270 ...
Страница 1386: ...1386 ...
Страница 1446: ...1446 ...
Страница 1448: ...1448 ...
Страница 1539: ...Gi1 2 2 STP PVST Dell Related Commands show running config displays the current configuration Service Provider Bridging 1539 ...
Страница 1540: ...1540 ...
Страница 1552: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell 1552 sFlow ...
Страница 1604: ...1604 ...
Страница 1642: ...1642 ...
Страница 1666: ...1666 ...
Страница 1676: ...1676 ...
Страница 1689: ... uplink state group creates an uplink state group and enables the tracking of upstream links Uplink Failure Detection UFD 1689 ...
Страница 1690: ...1690 ...
Страница 1710: ...1710 ...