Appendix
SiEN34-705
194
General Information
RX(Y)Q38P, 40P, 42P, 44P, 46P, 48P, 50P, 52P, 54PY1
RXYQ238P, 40P, 42P, 44P, 46P, 48P, 50P, 52P, 54PYL
C:
3D052262B
2 Wires
Cab
le
(T
ransmisson line)
2 Wires
Cab
le
(T
ransmisson line)
2 Wires
Cab
le
(T
ransmisson line)
2 Wires
Cab
le
(T
ransmisson line)
[UNIT 2]
[UNIT 3]
[UNIT 1]
2 Wires
Cab
le
(T
ransmisson line)
2 Wires
Cab
le
(T
ransmisson line)
[UNIT 2]
[UNIT 3]
[UNIT 1]
2 Wires
Cab
le
(T
ransmisson line)
2 Wires
Cab
le
(T
ransmisson line)
2 Wires
Cab
le
(P
o
w
er line)
2 Wires
Cab
le
(P
o
w
er line)
2 Wires
Cab
le
(P
o
w
er line)
2 Wires
Cab
le
(T
ransmisson line)
2 Wires
Cab
le
(T
ransmisson line)
2 Wires
Cab
le
(T
ransmisson line)
2 Wires
Cab
le
(P
o
w
er line)
2 Wires
Cab
le
(P
o
w
er line)
2 Wires
Cab
le
(P
o
w
er line)
Switch
Switch
Switch
Switch
Fuse
Fuse
Switch
Fuse
Fuse
Fuse
Switch
Switch
Switch
Fuse
Switch
Fuse
Switch
Fuse
Switch
Fuse
Switch
Fuse
Fuse
Fuse
Main
Switch
Main
Switch
Main
Switch
P
o
w
er supply
P
o
w
er supply
Main
Switch
P
o
w
er supply
OUTDOOR UNITS
OUTDOOR UNITS
When the po
w
e
r source is connected in
ser
ies betw
een the units
.
INDOOR UNITS
2 Wires
Cab
le
(P
o
w
er line)
2 Wires
Cab
le
(P
o
w
er line)
2 Wires
Cab
le
(P
o
w
er line)
2 Wires
Cab
le
(P
o
w
er line)
2 Wires
Cab
le
(P
o
w
er line)
INDOOR UNITS
P
o
w
er supply
Notes
1)
All wir
ing, components and mater
ials to be procured on the site m
ust
comply with the applicab
le local and national codes
.
2)
Use copper conductors only
3)
As f
or details
, see wir
ing diag
ram.
4)
Install circuit break
er f
or saf
ety
.
5)
All field wir
ing and components m
ust be pro
vided b
y
licensed
electr
ician.
6)
Unit shall be g
rounded in compliance with the applicab
le local and national codes
.
7)
Wir
ing sho
wn are gener
al points-of-connection guides only are not intended f
or or to include all details f
or or to specific
installation.
8)
Be sure to install the s
witch and the fuse to the po
w
e
r line of each equipment.
9)
Install the main s
w
itch that can interr
upt all the po
w
er sources in an integ
rated manner because this system consists of
the equipment utilizing the m
ultiple po
w
er sources
.
10)
The capacity of UNIT1 m
ust be larger than UNIT2 when the po
w
er source is connected in ser
ies betw
een the units
.
11)
If there e
xists the possibility of re
v
ersed phase
, lose phase
, momentar
y b
lac
k
out or the po
w
er goes on and off while the
product is oper
ating, attach a re
v
ersed phase protection circuit locally
.
Running the product in re
v
ersed phase ma
y break the compressor and other par
ts
.
When the po
w
er source is supplied to each
outdoor unit individually
.
Содержание RXYQ5PY1
Страница 2: ......
Страница 287: ...SiEN34 705 Heat Pump 60Hz RXYQ5 54P Installation Manual 281...
Страница 292: ...Heat Pump 60Hz RXYQ5 54P SiEN34 705 286 Installation Manual...
Страница 339: ...Operation Manual SiEN34 705 332 Operation Manual...