Troubleshooting
Teledyne Continental Motors, Inc.
TM
a.
Throttle................................................. IDLE
b.
Compare the sensor values for the odd numbered channels; the difference should
not exceed the values in Table 8-2. Repeat the comparison for the even numbered
channels.
c.
Throttle......................................... 1700 RPM
d.
Check the odd and even channel sensor readings for Tm, Pm and Pf, using the
tolerances in Table 8-2.
e.
Throttle ................................................ IDLE
13.
Perform a normal engine shutdown.
14.
Correct any discrepancies discovered during the check before returning the aircraft to
service.
15.
Disconnect the FADEC Level I Diagnostic interface cable from the FADEC or EDI
serial data port.
8-6.1.1. FADEC Power On Fault Isolation without an EDI
8-14
IOF-550 Permold Series Engine Maintenance Manual
1 April 2007