4 - 15
T U N
SETTING
Examples of carburetor setting depending on symptom
This should be taken simply for an example. It is necessary to set the carburetor while checking the operating condi-
tions of the engine.
Symptom
Setting
Checking
At full throttle
Hard breathing
Shearing noise
Whitish spark plug
↓
Lean mixture
Increase main jet calibration no.
(Gradually)
Discoloration of spark plug
→
If tan color, it is in good condition.
If cannot be corrected:
Clogged float valve seat
Clogged fuel hose
Clogged fuel cock
Check that the accelerator pump operates
smoothly.
At full throttle
Speed pick-up stops
Slow speed pick-up
Slow response
Sooty spark plug
↓
Rich mixture
Decrease main jet calibration no.
(Gradually)
Discoloration of spark plug
→
If tan color, it is in good condition.
If cannot be corrected:
Clogged air filter
Fuel overflow from carburetor
Lean mixture
Lower jet needle clip position.
(1 groove down)
The clip position is the jet needle groove
on which the clip is installed. The positions
are numbered from the top.
Check that the accelerator pump operates
smoothly. (except for rich mixture
symptom).
Rich mixture
Raise jet needle clip position.
(1 groove up)
1/4 ~ 3/4 throttle
Hard breathing
Lack of speed
Lower jet needle clip position.
(1 groove down)
1/4 ~ 1/2 throttle
Slow speed pick-up
Poor acceleration
Raise jet needle clip position.
(1 groove up)
Closed to 1/4 throttle
Hard breathing
Speed down
Use jet needle with a smaller diameter.
Slow-speed-circuit passage
Clogged
→
Clean.
Overflow from carburetor
Closed to 1/4 throttle
Poor acceleration
Use jet needle with a larger diameter.
Raise jet needle clip position.
(1 groove up)
Poor response in the low to
intermediate speeds
Raise jet needle clip position.
If this has no effect, lower the jet needle
clip position.
Poor response when throttle is
opened quickly
Check overall settings.
Use main jet with a lower calibration no.
Raise jet needle clip position.
(1 groove up)
If these have no effect, use a main jet with
a higher calibration no. and lower the jet
needle clip position.
Check air filter for fouling.
Check that the accelerator pump operates
smoothly.
Leaner
↑
(Standard)
↓
Richer
Jet needle
Clip
Groove 7
Groove 6
Groove 5
Groove 4
Groove 3
Groove 2
Groove 1
*
Summary of Contents for WR250F(W)
Page 51: ...1 26 GEN INFO MEMO...
Page 89: ...1 64 GEN INFO MEMO...
Page 189: ...2 96 SPEC MEMO...
Page 285: ...3 74 INSP ADJ MEMO...
Page 379: ...4 20 TUN MEMO...
Page 831: ...7 10 ELEC MEMO...
Page 847: ...7 26 ELEC MEMO...
Page 869: ...7 48 ELEC MEMO...
Page 877: ...7 56 ELEC MEMO...
Page 893: ...7 72 ELEC MEMO...
Page 903: ...7 82 ELEC MEMO...
Page 910: ......
Page 911: ......