11
Vector Control
11-16 | CFW700
P0163 – Local Reference Offset
P0164 – Remote Reference Offset
Adjustable
Range:
-999 to 999
Factory
Setting:
0
Properties:
Vector
Access groups
via HMI:
Description:
It adjusts the analog inputs (AIx) speed reference offset. Refer to the
P0165 – Speed Filter
Adjustable
Range:
0.012 to 1.000 s
Factory
Setting:
0.012 s
Properties:
Vector
Access groups
via HMI:
Description:
It adjusts the speed filter time constant. Refer to the
NOTE!
Generally, this parameter must not be changed. The increment in its value turns the system response
slower.
P0166 – Speed Regulator Differential Gain
Adjustable
Range:
0.00 to 7.99
Factory
Setting:
0.00
Properties:
Vector
Access groups
via HMI:
Description:
The differential action may minimize the effects of the application or removal of load, in the motor speed. Refer
to the
Table 11.3:
Differential gain action in the speed regulator
P0166
Diferential Gain Actuation
0.00
Inactive
0.01 to 7.99
Active
Summary of Contents for CFW700
Page 2: ......
Page 4: ......
Page 8: ...Summary...
Page 34: ...2 General Information 2 4 CFW700...
Page 38: ...3 About the CFW700 3 4 CFW700...
Page 56: ...7 Starting up and Settings 7 4 CFW700...
Page 58: ...8 Available Control Types 8 2 CFW700...
Page 78: ...10 VVW Control 10 8 CFW700...
Page 158: ...13 Digital and Analog Inputs and Outputs 13 28 CFW700...