19
Applications
19-24 | CFW700
P1016 – Multispeed Reference 6
Adjustable
Range:
0 to 18000 rpm
Factory
Setting:
1500 rpm
Properties:
Access groups
via HMI:
SPLC
Description:
Sets the speed reference 6 for the multispeed application.
P1017 – Multispeed Reference 7
Adjustable
Range:
0 to 18000 rpm
Factory
Setting:
1800 rpm
Properties:
Access groups
via HMI:
SPLC
Description:
Sets the speed reference 7 for the multispeed application.
P1018 – Multispeed Reference 8
Adjustable
Range:
0 to 18000 rpm
Factory
Setting:
1650 rpm
Properties:
Access groups
via HMI:
SPLC
Description:
Sets the speed reference 8 for the multispeed application.
19.5 3-WIRE START/STOP COMMAND APPLICATION
19.5.1 Description and Definitions
The CFW700 has the 3-WIRE START/STOP application that allows the inverter to be set as direct online start with
emergency button and retention contact.
This way, the digital input (DIx) programmed to “Function 1 of the Application (Start)” will be able to enable the
inverter with a single pulse in case the DIx set to “Function 2 of the Application (Stop)” is active. The inverter disables
the ramp when the digital input Stop is inactive. The picture below show how it works.
Summary of Contents for CFW700
Page 2: ......
Page 4: ......
Page 8: ...Summary...
Page 34: ...2 General Information 2 4 CFW700...
Page 38: ...3 About the CFW700 3 4 CFW700...
Page 56: ...7 Starting up and Settings 7 4 CFW700...
Page 58: ...8 Available Control Types 8 2 CFW700...
Page 78: ...10 VVW Control 10 8 CFW700...
Page 158: ...13 Digital and Analog Inputs and Outputs 13 28 CFW700...