![WEG CFW700 Programming And Troubleshooting Manual Download Page 140](http://html1.mh-extra.com/html/weg/cfw700/cfw700_programming-and-troubleshooting-manual_950676140.webp)
13
Digital and Analog Inputs and Outputs
13-10 | CFW700
P0270 - DI8 Function
Adjustable
Range:
0 = Not used
1 = Run/Stop
2 = General Enable
3 = Fast Stop
4 = FWD/REV
5 = LOC/REM
6 = JOG
7 = SoftPLC
8 = Ramp 2
9 = Speed/Torque
10 = JOG+
11 = JOG-
12 = No Ext. Alarm
13 = No Ext. Fault
14 = Reset
15 = Disable FlyStart
16 = DC Link Regul.
17 = Program. Off
18 = Load User 1
19 = Load User 2
20 = Application Function 1
21 = Application Function 2
22 = Application Function 3
23 = Application Function 4
24 = Application Function 5
25 = Application Function 6
26 = Application Function 7
27 = Application Function 8
Factory
Setting:
P0263=1
P0264=4
P0265=0
P0266=0
P0267=6
P0268=8
P0269=0
P0270=0
Properties:
cfg
Access groups
via HMI:
I/O
Description:
Those parameters make it possible to configure the functions of the digital inputs, according to the listed range.
Some notes regarding the Digital Input functions are presented next.
Run/Stop:
In order to assure the correct operation of this function, it is necessary to program P0224 and/
or P0227 in 1.
Local/Remote:
When programmed, this function activates “Local” when 0 V is applied to the input, and
“Remote” when +24 V are applied. It is also necessary to program P0220=4 (DIx).
Speed/Torque:
This function is valid for P0202=4 or 5 (Sensorless Vector Control or Vector with Encoder),
and “Speed” is selected with 0 V applied to the input, whereas “Torque” by applying 24 V.
When
Torque
is selected, the speed regulator parameters P0161 and P0162 become inactive
(*)
. Thus the Total
Reference becomes the Torque Regulator input. Refer to the
and
.
(*)
The speed regulator of the PID type is converted into a P type, with proportional gain 1.00 and a null integral
gain.
When
Speed
is selected, the gains of the speed regulator become again defined by P0161 and P0162. In the
applications with torque control it is recommended to follow the method described at the parameter P0160.
Summary of Contents for CFW700
Page 2: ......
Page 4: ......
Page 8: ...Summary...
Page 34: ...2 General Information 2 4 CFW700...
Page 38: ...3 About the CFW700 3 4 CFW700...
Page 56: ...7 Starting up and Settings 7 4 CFW700...
Page 58: ...8 Available Control Types 8 2 CFW700...
Page 78: ...10 VVW Control 10 8 CFW700...
Page 158: ...13 Digital and Analog Inputs and Outputs 13 28 CFW700...