61381
[Channel %1: ] Block %2: Coupling the spindle position with coordinate rotation around %4 not
executable
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
The alarm relates to the cross-measuring tasks measuring cycle function "Coupling of spindle position with coordinate
rotation around the infeed axis".
This function requires a positionable spindle.
Remedy:
If a positionable spindle is not available for holding the workpiece probe,
the function "Coupling the spindle position with coordinate rotation around the infeed axis"
can be deactivated with SD55740 $SCS_MEA_FUNCTION_MASK, bit 1=0.
61382
[Channel %1: ] Block %2 probe is attached to the machine, measuring variant is not possible
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
The measuring variant cannot be executed with a probe permanently mounted on the machine.
The selected measuring variant requires rotational positioning/alignment of the probe.
Remedy:
Select a measuring variant that does not require rotational positioning/alignment of the probe.
61383
[Channel %1: ] Block %2: Rotary axis 1: Diameter tolerance of calibration ball between
measurement %4 exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
see measured diameter in the parameters _OVR[75] to _OVR[77] or the value in SD $SCS_MEA_KIN_DM_TOL
Remedy:
Check the calibration data or recalibrate the 3D probe
Check the mechanical structure of the calibration ball in the machine
61384
[Channel %1: ] Block %2: Rotary axis 2: Diameter tolerance of calibration ball between
measurement %4 exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
see measured diameter in the parameters _OVR[75] to _OVR[77] or the value in SD $SCS_MEA_KIN_DM_TOL
Remedy:
Check the calibration data or recalibrate the 3D probe
Check the mechanical structure of the calibration ball in the machine
61385
[Channel %1: ] Block %2: Probe not calibrated in the coordinate system
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Probe has not been calibrated in the coordinate system set in MD52000 $MCS_DISP_COORDINATE_SYSTEM.
Remedy:
Calibrate the probe before measurement.
61401
[Channel %1: ] Block %2: Probe does not switch, traversing path limited by software limit position.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Explanation:
Remedy:
The position defined by a setpoint value cannot be reached as this would mean overrunning the software limit position.
- Check specified setpoint value.