61851
[channel %1: ] block %2: no suitable transformation set up: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The required transformation is not set up on this machine.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61852
[channel %1: ] block %2: transformation not set up for this plane: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Transformation not set up for the plane used. Change plane.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61853
[channel %1: ] block %2: incorrect plane for machining with rotary axis: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Machining cannot be executed on the rotary axis of the current plane. Change plane.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61854
[Channel %1: ] Block %2: Subprogram level too low for block search
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The subprogram level is too low for block search.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Execute block search with another block.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
486