61291
[Channel %1: ] Block %2: Linear axis of counterspindle not set up
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Set up the linear axis of the counter spindle in MD52206 $MCS_AXIS_USAGE.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61292
[Channel %1: ] Block %2: B axis not set up
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Set up the B axis in MD52206 $MCS_AXIS_USAGE.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61293
[Channel %1: ] Block %2: Tool %4 has no spindle rotation direction
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select spindle rotation direction in tool list.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61294
[Channel %1: ] Block %2: Active radius/diameter setting does not match reset setting
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Before starting up the program, set G group 29 (DIAMON, DIAMOF etc.) to reflect the corresponding reset value.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
426