10656
[Channel %1: ] Axis %2 gantry slave axis dynamically overloaded
Parameters:
%1 = Channel number
%2 = Axis
Explanation:
The indicated gantry slave axis is dynamically overloaded, i.e. the slave axis cannot follow the master axis dynamically
Reaction:
Mode group not ready.
Local alarm reaction.
Channel not ready.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Compare the axial machine data of the gantry slave axis with
the data of the gantry master axis
Programm
continuation:
Restart part program. Clear alarm with the RESET key in all channels of this mode group. Restart part program.
10657
[Channel %1: ] Axis %2 power OFF in the gantry error limit exceeded status
Parameters:
%1 = Channel number
%2 = Axis
Explanation:
Gantry error limit exceeded status (alarm 10653) has been switched off.
The error can only be removed by deleting MD37135 $MA_GANTRY_ACT_POS_TOL_ERROR or by
deactivating the extended monitoring (MD37150 $MA_GANTRY_FUNCTION_MASK Bit0).
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
1. Remove a mechanical misalignment
2. Check axis (uneven mechanical movement?)
3. Delete MD37135 $MA_GANTRY_ACT_POS_TOL_ERROR or deactivate the extended monitoring
4. MD37120 $MA_GANTRY_POS_TOL_ERROR is set incorrectly
If the MD is changed, a Power ON will be required.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
10658
[Channel %1: ] Axis %2 impermissible axis status %3.
Parameters:
%1 = Channel number
%2 = Axis number
%3 = Error ID and gantry unit.
Explanation:
Error ID and gantry unit
- 30XX => Gantry group cannot be closed, as not all gantry axes are in one channel.
- 40XX => Gantry group cannot be closed, as the gantry axes have different axis states (the axis is assigned to the PLC,
for example).
- 50XX => Gantry group is to change channel due to a PLC request, not all gantry axes are known in the new channel.
- 60XX => Gantry group is to be transferred to the channel due to an NC program request, but the channel does not know
all the gantry axes.
- 70XX => Gantry group cannot be closed, as movement is pending for at least one gantry axis.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Local alarm reaction.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
105