Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Correct the name used (write error)
- Use a higher-level software system for reduced functions
- Check the definitions of variables, subroutines and macros
- Declare a subroutine with EXTERN; load the subroutine to SPF-Dir
- Check the interface definition of the subroutine
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
12552
[Channel %1: ] Block %2 tool/magazine OEM parameter not defined. Option not set.
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The programmed $TC_... Cx system variable is not known in the control.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Correct the name used (writing error)
- $TC_DPCx, $TC_TPCx, $TC_MOPCx, $TC_MAPCx, $TC_MPPCx, $TC_DPCSx, $TC_TPCSx, $TC_MOPCSx,
$TC_MAPCSx, $TC_MPPCSx; with x=1,...10
- These are the OEM parameters of the tools magazines, The corresponding machine data value is set to < 10, or the
option 'TM OEM parameters' has not been set.
- Use correct parameter number, or - if the name cannot be changed - set machine data correction (see MD18096
$MN_MM_NUM_CC_TOA_PARAM, ... MD18206 $MN_MM_NUM_CCS_TOA_PARAM, ...). )
- Check the option (machine data are only effective when the option is enabled).
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
12553
[Channel %1: ] Block %2 name %3 option/function is not active
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Explanation:
The option (if MD10711 $MN_NC_LANGUAGE_CONFIGURATION = 1) or the NC function (if MD10711
$MN_NC_LANGUAGE_CONFIGURATION = 3)
related to this language command is not active.
But the name of the language command is known.
Each programming of this language command is rejected with this alarm.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the "Compensation block" function by pressing the PROGRAM CORRECT softkey. The
cursor positions itself on the incorrect block.
- Correct the name used (in the case of a typing error).
- Activate the NC function (if a language command of an inactive function has been programmed).
- Enable the option required (if a language command of a function with a non-enabled option has been programmed).
See also MD10711 $MN_NC_LANGUAGE_CONFIGURATION.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
163