26075
[Channel %1: ] Block %2 Axis %3 not available for the NC program, as exclusively controlled by
the PLC
Parameters:
%1 = Channel
%2 = Block number, label
%3 = Axis, spindle
Explanation:
The axis is exclusively controlled by the PLC. Therefore, the axis is not available for the NC program.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Have the axis not exclusively controlled by the PLC, but only temporarily. Change MD30460
$MA_BASE_FUNCTION_MASK, bit 4.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
26076
[Channel %1: ] Block %2 Axis %3 not available for NC program, firmly assigned PLC axis
Parameters:
%1 = Channel
%2 = Block number, label
%3 = Axis, spindle
Explanation:
The axis is a firmly assigned PLC axis. The axis is therefore not available for the NC program.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Do not define axis as a firmly assigned PLC axis. Change of MD30460 $MA_BASE_FUNCTION_MASK bit5.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
26077
[Channel %1: ] Axis %2 not available for the NC program, as exclusively controlled by the PLC
Parameters:
%1 = Channel
%2 = Axis, spindle
Explanation:
The axis is exclusively controlled by the PLC. Therefore, the axis is not available for the NC program.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Have the axis not exclusively controlled by the PLC, but only temporarily. Change MD30460
$MA_BASE_FUNCTION_MASK, bit 4.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
26078
[Channel %1: ] Axis %2 not available for NC program, firmly assigned PLC axis
Parameters:
%1 = Channel
%2 = Axis, spindle
Explanation:
The axis is a firmly assigned PLC axis. The axis is therefore not available for the NC program.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Do not define axis as a firmly assigned PLC axis. Change of MD30460 $MA_BASE_FUNCTION_MASK bit5.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
357