- 84. Parameterization of the third orientation axis as a spindle is not permissible.
- 87. Parameterization of the first orientation axis as a Hirth axis is incorrect, i.e. at least one of the machine data MD30502
$MA_INDEX_AX_DENOMINATOR, MD30501 $MA_INDEX_AX_NUMERATOR, or MD30330 $MA_MODULO_RANGE
(for modulo axes) is zero.
- 88. Parameterization of the second orientation axis as a Hirth axis is incorrect. The error conditions are the same as
for error number 87.
- 89. Parameterization of the third orientation axis as a Hirth axis is incorrect. The error conditions are the same as for
error number 87.
- 100. The maximum number of kinematic elements (sum of linear axes, rotary axes and constant elements) has been
exceeded. In this case, a sequence of constant elements in a chain, which is not interrupted by an axis, is only considered
as one element.
A maximum of 15 kinematic elements is currently permissible for orientation transformations.
- 101. The maximum number of rotary axes for the kinematic chains for the definition of a transformation has been
exceeded.
- 103. The maximum number of elements in the definition of the kinematic chain for the tool has been exceeded.
- 104. The maximum number of elements in the definition of the kinematic chain for the workpiece has been exceeded.
A maximum of 6 rotary axes is currently permissible for orientation transformations.
- 106. The maximum permissible number of chain elements for internal representation of the machine kinematics has
been exceeded.
- 200. At the end of the part chain, a correction element is defined although bit 7 is set in $NT_CNTRL[n] (close part
chain).
- 201. At the end of the tool chain, a correction element is defined although bit 8 is set in $NT_CNTRL[n] (close tool chain)
- 300. The chain element to which $NT_CORR_ELEM_P[n, 0] refers was not found.
- 301. The chain element to which $NT_CORR_ELEM_P[n, 1] refers was not found.
- 302. The chain element to which $NT_CORR_ELEM_P[n, 2] refers was not found.
- 303. The chain element to which $NT_CORR_ELEM_P[n, 3] refers was not found.
- 310. The chain element to which $NT_CORR_ELEM_T[n, 0] refers was not found.
- 311. The chain element to which $NT_CORR_ELEM_T[n, 1] refers was not found.
- 312. The chain element to which $NT_CORR_ELEM_T[n, 2] refers was not found.
- 313. The chain element to which $NT_CORR_ELEM_T[n, 3] refers was not found.
- 320. The chain element to which $NT_CORR_ELEM_P[n, 0] refers is not in the associated section.
- 321. The chain element to which $NT_CORR_ELEM_P[n, 1] refers is not in the associated section.
- 322. The chain element to which $NT_CORR_ELEM_P[n, 2] refers is not in the associated section.
- 323. The chain element to which $NT_CORR_ELEM_P[n, 3] refers is not in the associated section.
- 330. The chain element to which $NT_CORR_ELEM_T[n, 0] refers is not in the associated section.
- 331. The chain element to which $NT_CORR_ELEM_T[n, 1] refers is not in the associated section.
- 332. The chain element to which $NT_CORR_ELEM_T[n, 2] refers is not in the associated section.
- 333. The chain element to which $NT_CORR_ELEM_T[n, 3] refers is not in the associated section.
- 10000. Invalid redundant rotary axis. Only one redundant rotary axis is permissible for orientation transformation (for the
time being). This rotary axis must be the first axis in the kinematic chain.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Define valid transformation data record.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
4349
[Channel %1: ] No free memory space available for transformations.
Parameters:
%1 = Channel number
%2 = Number of the transformations already active
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
74