61920
%[[Channel %1: ] Block %2: %]Error during contour milling %4
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
3020: No more memory is available
3022: The contour is incorrect
3023: Check contour (contour may contain too small elements)
3356: The residual material cannot be removed completely with the tool used.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
3020, 3022, and 3023: Check contour and technological data
3356: A tool with a smaller diameter, with which the residual material can be removed completely, must be used for residual
machining.
Call the SIEMENS hotline
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61930
%[[Channel %1: ] Block %2: %]No contour available
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check contour call
- Check whether the contours exist in the program storage (workpieces, subroutines or part
programs)
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61931
%[[Channel %1: ] Block %2: %]Contour not closed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check whether the contours are closed
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61932
%[[Channel %1: ] Block %2: %]Selfcutting contour
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
496