Explanation:
An error occurred on the selection of JOG Retract, which is described in more detail by the error code (parameter%4):
List of error codes:
1: No retract data available
2: Selection is active during taper turning
3: Error preparing the initialization blocks. The additional info (parameter %3) states the initialization step in which the
error occurred. The alarm output immediately before also refers to this initialization step:
100: Error synchronizing the preprocessing/main run
101: Error selecting the tool length compensation
102: Error selecting the transformation
103: Error generating the tool frame
104: Error generating the tapping block
105: Error replacing geometry axes
4: The position of the axis stated in the additional info does not have the status "synchronized" or "restored"
5: The axis stated in the additional info is already assigned in another channel by JOG Retract
6: The geometry axis stated by the selection of JOG Retract does not exist
7: MD 20110 $MC_RESET_MODE_MASK bit 0 is not set
8: Thread cutting is active. The thread direction cannot be explicitly assigned to a JOG axis
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The following conditions have to be fulfilled in order to select JOG Retract:
- A program execution with active tool offset has been canceled by Reset or PowerOff
- PLC signal DB3300.DBX4005.5 (Retract data available) or OPI variable retractState bit 1 is set
- JOG mode is active
- The channel in which JOG Retract is to be selected is in Reset state
- The function "Taper turning" must not be active when JOG Retract is selected
- Synchronized or restored axis positions must be present for the axes involved in the transformation
If necessary, activate position restoration for incremental encoders (MD34210 $MA_ENC_REFP_STATE[]=3)
- MD 20110 $MC_RESET_MODE_MASK bit 0 must be set (default value)
In the case of an error, the alarm must be acknowledged with Reset. The selection can then be repeated, observing the
above-mentioned conditions.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
14750
[Channel %1: ] Block %2 too many auxiliary functions programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
More than 10 auxiliary functions have been programmed in an NC block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check whether all auxiliary functions are necessary in one block - modal functions need not be repeated. Create separate
auxiliary function block or divide the auxiliary functions over several blocks.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14751
[Channel %1: ] Block %2 resources for motion synchronous actions not sufficient (code: %3)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Identifier
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
216