Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14783
[Channel %1: ] Block %2 coordinate system-specific working area limitation is not active
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
An attempt is made in the block to activate a group of the coordinate system-specific working area limitation.
However, this group is not set up (see MD28600 $MC_MM_NUM_WORKAREA_CS_GROUPS).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
The NC program is stopped. The G code of the group WALCS01 - WALCS10 can be changed.
Remedy:
- Modify part programm.
- Activate more coordinate system-specific working area limitations.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14784
[Channel %1: ] Block %2 motion synchronous action: %3 function not possible
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
Explanation:
It is not possible to execute the function:
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
14790
[Channel %1: ] Block %2 axis %3 programmed by PLC
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis
Explanation:
In the NC block, an axis has been programmed that is already being traversed by the PLC.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Modify part program, do not use this axis.
- Stop traversing motion of the axis by the PLC, modify part program (insert WAITP).
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14800
[Channel %1: ] Block %2 programmed path speed less or equal to zero
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Zero or a negative F or FZ value has been programmed in conjunction with the G functions G93, G94, G95 or G96. The
path velocity may be programmed in the range of 0.001 to 999 999.999 [mm/min, mm/rev, mm/tooth, deg/min, deg/rev]
for the metric input system and 0.000 1 to 39 999.999 [inch/min, inch/rev, inch/tooth] for the inch input system.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
222
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2