Programm
continuation:
Clear alarm with the RESET key. Restart part program
22055
[Channel %1: ] Block %3 spindle %2 configured positioning speed is too high
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
Explanation:
The current position is not referenced with the measuring system position although reference is made to it.
Reaction:
Alarm display.
Remedy:
Correct NC part program. Create the zero mark synchronization by positioning, by rotation (at least 1 revolution) in speed
control mode or G74 before switching the alarm generating function on.
Programm
continuation:
Clear alarm with the Delete key or NC START.
22060
[Channel %1: ] Position control expected for axis/spindle %2
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Explanation:
The programmed coupling type (DV, AV) or the programmed function requires position control.
Reaction:
Alarm display.
Remedy:
Activate position control, e.g. by programming SPCON.
Programm
continuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
22062
[Channel %1: ] Axis %2 reference point approach: zero marker search velocity (MD) is not reached
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Explanation:
The configured zero marker search velocity is not reached.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Check active spindle speed limitations. Configure a lower zero marker search velocity MD34040
$MA_REFP_VELO_SEARCH_MARKER. Check the tolerance range for the actual velocity MD35150
$MA_SPIND_DES_VELO_TOL. Set a different referencing mode MD34200 $MA_ENC_REFP_MODE != 7.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
22064
[Channel %1: ] Axis %2 reference point approach: zero marker search velocity (MD) is too high
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Explanation:
The configured zero marker search velocity is too high. The encoder limit frequency is exceeded for the active measuring
system.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Configure a lower zero marker search velocity MD34040 $MA_REFP_VELO_SEARCH_MARKER. Check the encoder
frequency configuration MD36300 $MA_ENC_FREQ_LIMIT and MD36302 $MA_ENC_FREQ_LIMIT_LOW. Set a different
referencing mode MD34200 $MA_ENC_REFP_MODE=7.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
330
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2