4030
[Channel %1: ] Identifier missing in machine date %2[%3]
Parameters:
%1 = Channel number
%2 = String: MD identifier
%3 = Index: MD array index
Explanation:
An axis identifier is expected for the displayed MD in accordance with the axis configuration in the MD20070
$MC_AXCONF_MACHAX_USED and MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Check axis configuration and enter the missing identifier into the MD or, should the axis not exist, specify for this channel
axis the machine axis 0 in the channel-specific MD20070 $MC_AXCONF_MACHAX_USED. If this concerns a geometry
axis that is not to be used (this applies only for 2-axis machining, e.g. on turning machines), then channel axis 0 must be
entered additionally in the channel-specific MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB.
Programm
continuation:
Switch control OFF - ON.
4032
[Channel %1: ] Wrong identifier for facing axis in %2
Parameters:
%1 = Channel number
%2 = String: MD identifier
Explanation:
According to the axis configuration in MD20150 $MC_GCODE_RESET_VALUES or MD20100
$MC_DIAMETER_AX_DEF, a facing axis identifier is expected at the specified location.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Add the correct identifier.
Programm
continuation:
Switch control OFF - ON.
4040
[Channel %1: ] Axis identifier %2 not consistent with machine data %3
Parameters:
%1 = Channel number
%2 = String: Axis identifier
%3 = String: MD identifier
%4 = There are not enough channel axes entered in the MD displayed.
Explanation:
The use of the specified axis identifier in the displayed MD is not consistent the channel's axis configuration stated in the
MD20070 $MC_AXCONF_MACHAX_USED and MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB.
Only with active "OEM transformation" compile cycle: There are not enough channel axes entered in the MD displayed.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
55