Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check if a guide channel has been defined
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61744
%[[channel %1: ] block %2: %]Following channel for two-channel cutting missing
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check if a following channel has been defined
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61745
%[[channel %1: ] block %2: %]Two-channel cutting in two guide channels (%4) active
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check if two guide channels are active
- Check if two-channel cutting is active simultaneously in more than two channels
- Two channels only may be active: a guide and a following channel
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61746
%[[channel %1: ] block %2: %]Two-channel cutting active already in the channels (%4)
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check if two-channel cutting is active simultaneously in more than two channels.
- Two channels only may be active simultaneously: a guide and a following channel.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61747
%[[channel %1: ] block %2: %]Incorrect guide channel for two-channel cutting (%4)
Parameters:
%1 = Channel number
%2 = Block number, label
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
476