4111
PLC cycle increased to %1 ms
Parameters:
%1 = String (new PLC cycle time)
Explanation:
The PLC cycle divisor was set to a value which was not an integral multiple of the IPO cycle divisor. The divisor (MD10074
$PLC_IPO_TIME_RATIO) has been increased.
For PROFIBUS/PROFINET: MD10074 $PLC_IPO_TIME_RATIO has been modified because of the modified DP cycle in
the SDB (MD10050 $SYSCLOCK_CYCLE_TIME).
Reaction:
Alarm display.
Remedy:
MD10074 $MN_PLC_IPO_TIME_RATIO has been modified.
Modify machine data
Programm
continuation:
Clear alarm with the RESET key. Restart part program
4112
Servo cycle changed to %1 ms
Parameters:
%1 = String (new servo cycle time)
Explanation:
For PROFIBUS/PROFINET only:
MD10060 $POSCTRL_SYSCLOCK_TIME_RATIO has been modified because of the modified DP cycle in the SDB
(MD10050 $SYSCLOCK_CYCLE_TIME).
Reaction:
Alarm display.
Remedy:
MD10060 $MN_POSCTRL_SYSCLOCK_TIME_RATIO has been modified.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
4113
Sysclock cycle changed to %1 ms
Parameters:
%1 = String (new PLC cycle time)
Explanation:
For PROFIBUS/PROFINET only:
MD10050 $SYSCLOCK_CYCLE_TIME has been modified because of the modified DP cycle in the SDB.
Reaction:
Alarm display.
Remedy:
MD10050 $MN_SYSCLOCK_CYCLE_TIME has been modified.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
4114
Error in DP cycle of the SDB
Parameters:
%1 = String (new PLC cycle time)
Explanation:
For PROFIBUS/PROFINET only:
The DP cycle in the SDB contains an error and cannot be set. The default value of
MD10050$MN_SYSCLOCK_CYCLE_TIME is set.
Reaction:
Alarm display.
Remedy:
Correct the SDB
Programm
continuation:
Switch control OFF - ON.
4115
Time ratio communication to Ipo changed to %1
Parameters:
%1 = String (new PLC cycle time)
Explanation:
The value of the MD10072 $MN_COM_IPO_TIME_RATIO has been adapted. This can only occur, if the value of the
machine data is smaller than one and the time thus calculated is no multiple of the position control cycle.
Reaction:
Alarm display.
Remedy:
The MD10072 $MN_COM_IPO_TIME_RATIO has been adapted. Please check to ensure that the calculated value is
correct.
Programm
continuation:
Clear alarm with the RESET key. Restart part program