10917
[Channel %1: ] Block %2 Warning of COMPSURF function (code %3, details %4)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Error code
%4 = Error details
Explanation:
COMPSURF was only able to work with restrictions.
The warning is only displayed if MD11411 $MN_ENABLE_ALARM_MASK bit1 is set.
Reaction:
No alarm reaction.
Warning display.
Remedy:
1: Modify parameterization (smaller tolerance, larger block buffer).
Programm
continuation:
Clear alarm with the Delete key or NC START.
10930
[Channel %1: ] Block %2 interpolation type not allowed in stock removal contour
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The following types of interpolation are allowed in the contour program for stock removal: G00, G01, G02, G03, CIP, CT
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
In the contour subroutine, program only path elements that consist of straight lines and arcs.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
10931
[Channel %1: ] Block %2 incorrect stock removal contour
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The following errors occurred in the subroutine for the contour during stock removal:
- Full circle
- Overlapping contour elements
- Wrong start position
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The errors listed above must be corrected in the subroutine for the stock removal contour.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
10932
[Channel %1: ] Block %2 preparation of contour has been restarted
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The first contour preparation/contour decoding run must be terminated with EXECUTE.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program the keyword EXECUTE to terminate the contour preparation in the part program before again calling up contour
segmentation (keyword CONTPRON).
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
134
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2