4215
[Channel %1: ] Spindle %2 declaration as modulo axis missing
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Explanation:
The spindle functionality requires a modulo axis (positions in [deg]).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Set MD30310 $MA_ROT_IS_MODULO.
Programm
continuation:
Switch control OFF - ON.
4220
[Channel %1: ] Spindle %2 declared repeatedly
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Explanation:
The spindle number exists more than once in the channel.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
The spindle number is stored in the axis-specific MD35000 $MA_SPIND_ASSIGN_TO_MACHAX. The channel to which
this machine axis/spindle is assigned is listed in the machine axis index. (The machine axis number is given in the channel-
specific MD20070 $MC_AXCONF_MACHAX_USED).
Programm
continuation:
Switch control OFF - ON.
4225
[Channel %1: ] Axis %2 declaration as rotary axis missing
Parameters:
%1 = Channel number
%2 = Axis name, axis number
Explanation:
The modulo functionality requires a rotary axis (positions in [deg]).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Set MD30300 $MA_IS_ROT_AX.
Programm
continuation:
Switch control OFF - ON.
4230
[Channel %1: ] Data alteration from external not possible in current channel state
Parameters:
%1 = Channel number
Explanation:
It is not allowed to enter this data while the part program is being executed (e.g. setting data for working area limitation or
for dry run feedrate).
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
66