Remedy:
- Reduce the number of communication jobs taking place at the same time or increase MD10134
$MN_MM_NUM_MMC_UNITS
- Restart communication job.
Please inform the authorized personnel/service department. No remedial measures are possible - the operation triggering
the alarm message has to be repeated. Clear the alarm display with Cancel.
Programm
continuation:
Clear alarm with the Delete key or NC START.
6000
Memory reorganized using standard machine data
Explanation:
The memory management was not able to allocate the NC user memory with the values in the machine data. It did not
have enough memory available because the total memory available is provided as dynamic and static memory for the NC
user (e.g. for macro definitions, user variables, number of tool offsets, number of directories and files etc.).
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Redefine the NC memory structure!
A specific MD for NC user memory allocation cannot be stated to be the cause of the alarm. The MD initiating the alarm
therefore has to be determined on the basis of the default values in the machine data by changing the user-specific memory
structure step by step.
Usually, it is not just one single MD that has been set too large. Therefore it is advisable to reduce the memory area by a
certain proportion in several MDs.
Programm
continuation:
Restart part program. Clear alarm with the RESET key in all channels of this mode group. Restart part program.
6010
[Channel %1: ] Data block %2 not or not completely created, error code %3
Parameters:
%1 = Channel number
%2 = String (block name)
%3 = Internal error code
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
79