61116
[Channel %1: ] Block %2: Approach or retract path = 0
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The approach or retract path has been specified with zero.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check parameter _LP1 or _LP2.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61117
%[[Channel %1: ] Block %2: %]Active tool radius is smaller than or equal to zero
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The radius of the active tool is negative or zero.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify radius.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61118
[Channel %1: ] Block %2: Length or width = 0
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The length or width of the milling area is illegal.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check parameters _LENG and _WID.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61119
[Channel %1: ] Block %2: Nominal or core diameter programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The nominal or core diameter was incorrectly programmed.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check thread geometry.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
385