Programm
continuation:
Switch control OFF - ON.
300406
Problem in the non-cyclic communication for basic address %1, additional information %2, %3,
%4
Explanation:
For PROFIdrive only:
A problem occured during the non-cyclic communication with the logical start address. The additional information defines
the location of the problem. If the logical start address 0 is output, only the additional information is relevant.
Reaction:
Alarm display.
Warning display.
Remedy:
Please inform the authorized personnel/service department. The alarm can be suppressed with MD11411
$MN_ENABLE_ALARM_MASK bit 1 = 0
Place a support request with the error text under: http://www.siemens.com/automation/support-request
Programm
continuation:
Clear alarm with the Delete key or NC START.
300410
Axis %1 drive %2 error when storing a file (%3, %4)
Parameters:
%1 = NC axis number
%2 = Drive number
%3 = Error code 1
%4 = Error code 2
Explanation:
An attempt to save a data block, e. g. the result of a measuring function, in the file system has failed.
On error code 1 == 291: An error occurred during preparation of the ACC information. Basic information prepared on the
drive contains an error or has an unknown format.
On error code 1 == 292: Memory shortage during preparation of the ACC information.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
- Please inform the authorized personnel/service department.
- Create more space in the file system. It is normally sufficient to delete 2 NC programs or to free 4 - 8 Kbytes of memory.
If these remedies do not work, it will be necessary to increase the number of files per directory or the size of the file system
itself (this will require a complete data backup).
- Change settings of machine data
- 18280 $MM_NUM_FILES_PER_DIR
- 18320 $MM_NUM_FILES_IN_FILESYSTEM
- 18321 $MM_MAXNUM_SYSTEM_FILES_IN_FILESYSTEM
- 18350 $MM_USER_FILE_MEM_MINIMUM
- and, if necessary, of
- 18270 $MM_NUM_SUBDIR_PER_DIR,
- 18310 $MM_NUM_DIR_IN_FILESYSTEM,
- Power On
- Reload saved data
- On error code 1 == 291: Replace the drive software and use version with suitable ACC basic information.
- On error code 1 == 292: Replace the drive software and use fewer different versions of the drive software.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
300412
Error when storing a file (%1, %2)
Parameters:
%1 = Error code 1
%2 = Error code 2
Explanation:
An attempt to save a data block, e.g. the result of a measuring function, in the file system has failed.
Reaction:
Interface signals are set.
Alarm display.
SINUMERIK 808D ADVANCED alarms
5.4 Drive alarms
Diagnostics Manual
510