Programm
continuation:
Clear alarm with the RESET key. Restart part program
14622
[Channel %1: ] Access to file %2 disrupted by %3 %4
Parameters:
%1 = Channel number
%2 = File which could not be accessed
%3 = Function with which it is accessed
%4 = Error message
Explanation:
The program is stored on an external data medium (CF card, network drive, USB device). An error occurred when the
program was accessed.
Possible cause of error: network disturbance.
Reaction:
Alarm display.
Remedy:
- Rectify network disturbances if applicable
Programm
continuation:
Clear alarm with the Delete key or NC START.
14623
The EES library does not exist
Explanation:
The EES library does not exist; no part programs can be executed with EES.
Reaction:
Channel not ready.
Alarm display.
Remedy:
Load EES library
Programm
continuation:
Switch control OFF - ON.
14624
The EES library is incompatible.
Explanation:
The EES library is incompatible; no part programs can be executed with EES.
Reaction:
Channel not ready.
Alarm display.
Remedy:
Replace EES library
Programm
continuation:
Switch control OFF - ON.
14625
[Channel %1: ] Block %2 Problems in EES mode accessing file %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = File which could not be accessed
Explanation:
The program is located on an external data medium (network drive, USB device). Problems occurred when accessing the
program.
Possible cause or error: network fault.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- if necessary, remedy network faults und resume program
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14650
[Channel %1: ] Block %2 SETINT instruction with invalid ASUB input
Parameters:
%1 = Channel number
%2 = Block number, label
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
212
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2