Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program the indexing axis position in the NC part program in accordance with the length of the current position table, or
add the required value to the position table and adjust the length of the list.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
17600
[Channel %1: ] Block %2 preset on transformed axis %3 not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Explanation:
The programmed preset key axis is involved in the current transformation. This means that setting the actual value memory
(PRESET) is not possible for this axis (valid for PRESETON and PRESETONS).
Example:
Machine axis A should be set to the new actual value A 100 at the absolute position A 300.
:
N100 G90 G00 A=300
N101 PRESETON A=100
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Avoid preset actual value memory for axes which are participating in a transformation or deselect the transformation with
the keyword TRAFOOF.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
17601
[Channel %1: ] Block %2 motion synchronous action: %3 preset not possible on axis %4
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
%4 = Axis name, spindle number
Explanation:
Actual value preset not possible for this axis because
- the axis is moving
- the axis is involved in a transformation
- the axis is currently being monitored for collision
- the spindle traverse movement has not yet been completed
- reference point approach (G74) is active
- the geometry axis is not in the 'neutral axis' state
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Avoid actual value preset or put the relevant geometry axis in the 'neutral axis' state in good time with RELEASE(...).
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
285