Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14097
[Channel %1: ] Block %2 string cannot be converted to AXIS type
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The called function AXNAME - conversion of the transferred parameters of the STRING type to an axis name (return value)
of the AXIS type - has not found this axis identifier in the machine data.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Check the transferred parameter (axis name) of the function
AXNAME to determine whether a geometry, channel or machine axis of this name has been configured by means of the
machine data:
MD10000 $MN_AXCONF_MACHAX_NAME_TAB
MD20060 $MC_AXCONF_GEOAX_NAME_TAB
MD20080 $MC_AXCONF_CHANAX_NAME_TAB
Select the transfer string in accordance with the axis name, and change the axis name in the machine data if necessary.
(If a change of name is to take place via the NC part program, this change must first be validated by means of a "POWER-
ON").
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14098
[Channel %1: ] Block %2 conversion error: no valid number found
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The string is not a valid INT or REAL number.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program. If it is an entry, then you can check whether the string is a number via the preset function ISNUMBER
(with the same parameter).
Programm
continuation:
Clear alarm with the RESET key. Restart part program
14099
[Channel %1: ] Block %2 result in string concatenation too long
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The result of string chaining returns a string which is greater than the maximum string length laid down by the system.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Adapt part program. With the function STRLEN, it is also possible to query the size of the sum string before executing the
chaining operation.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
195